Calibration Techniques for MQ Gas Sensors to Improve Gas Detection Accuracy (Review Article)
Muthanna Journal for Agricultural Sciences · 15.06.2026 · 13 (1) · 1-11
DOI: 10.52113/mjas04/13.1/52 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muthanna Journal for Agricultural Sciences, erschienen am 15.06.2026. Verfasst von Saif Rawdhan.
Abstract (Originalsprache)
Sensors in environmental and agricultural monitoring systems are widely used due to their low-cost and ease of integration with microcontrollers and the Internet of Things (IoT). However, relying on real-time readings from these sensors can lead to inaccurate results due to their susceptibility to various environmental factors such as temperature, humidity, sensor age, and manufacturing variations between different units. Therefore, this research focus on calibrating a group of sensors, including the MQ-2, MQ-7, MQ-135, MQ-136, and MQ-137, with the aim of improving measurement accuracy and increasing the reliability of the resulting data. The calibration process involved determining the reference resistance (Ro) of each sensor under standard operating conditions, then calculating the resistance ratio (Rs/Ro) and using calibration curves derived from the technical data sheets to convert the electrical readings into actual gas concentration values. The sensors' responses to several target gases were evaluated. The results showed that applying calibration procedures significantly improved measurement accuracy and reduced the deviation between measured and reference values. It also contributed to increased sensor stability during continuous operation. The results further indicated that each sensor has different response characteristics, requiring specific calibration processes to achieve optimal performance. This study underscores the importance of initial and periodic calibration of MQ sensors before their deployment in practical applications to ensure reliable data for use in environmental monitoring systems, smart agriculture, and IoT applications.
Zitieren
APA
Rawdhan, S. (2026). Calibration Techniques for MQ Gas Sensors to Improve Gas Detection Accuracy (Review Article). Muthanna Journal for Agricultural Sciences, 13(1), 1-11. https://doi.org/10.52113/mjas04/13.1/52
Vancouver
Rawdhan S. Calibration Techniques for MQ Gas Sensors to Improve Gas Detection Accuracy (Review Article). Muthanna Journal for Agricultural Sciences. 2026;13(1):1-11. doi:10.52113/mjas04/13.1/52
BibTeX
@article{Rawdhan2026,
author = {Rawdhan, Saif},
title = {Calibration Techniques for MQ Gas Sensors to Improve Gas Detection Accuracy (Review Article)},
journal = {Muthanna Journal for Agricultural Sciences},
year = {2026},
volume = {13},
number = {1},
pages = {1--11},
doi = {10.52113/mjas04/13.1/52}
}
EUVIMED