Improving TDS Sensor Accuracy in an IoT-Based Fertigation Prototype Using Polynomial Regression Calibration and Interpolation
International Journal of Engineering, Science and Information Technology · 20.01.2026 · 6 (1) · 36-43
DOI: 10.52088/ijesty.v6i1.1776 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Engineering, Science and Information Technology, online erschienen am 20.01.2026. Verfasst von Arif Harjanto und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Accurate measurement of Total Dissolved Solids (TDS) is a critical requirement for hydroponic nutrient management, especially in automated fertigation systems that adjust nutrient concentrations based on plant age. However, non-industrial TDS sensors often exhibit significant fluctuations and non-linear errors, leading to unreliable nutrient dosing. This study proposes a calibration approach using second-order polynomial regression combined with interpolation to improve the accuracy of TDS measurements in an IoT-based fertigation prototype for lettuce hydroponics. The calibration was performed using reference TDS solutions and a digital TDS meter to ensure accurate measurements. The results show that the Mean Absolute Percentage Error (MAPE) decreased from 24.771% to 7.5768% during calibration, demonstrating a significant improvement in measurement accuracy. The calibrated sensor readings fall within the acceptable range for hydroponic nutrient control (±10%). This method provides a low-cost, reliable alternative for improving sensor accuracy in IoT fertigation systems.
Zitieren
APA
Harjanto, A., Nugroho, H., Ainurrosyidah, A. A., & Burhandenny, A. E. (2026). Improving TDS Sensor Accuracy in an IoT-Based Fertigation Prototype Using Polynomial Regression Calibration and Interpolation. International Journal of Engineering, Science and Information Technology, 6(1), 36-43. https://doi.org/10.52088/ijesty.v6i1.1776
Vancouver
Harjanto A, Nugroho H, Ainurrosyidah AA, Burhandenny AE. Improving TDS Sensor Accuracy in an IoT-Based Fertigation Prototype Using Polynomial Regression Calibration and Interpolation. International Journal of Engineering, Science and Information Technology. 2026;6(1):36-43. doi:10.52088/ijesty.v6i1.1776
BibTeX
@article{Harjanto2026,
author = {Harjanto, Arif and Nugroho, Happy and Ainurrosyidah, Aprilia Amrina and Burhandenny, Aji Ery},
title = {Improving TDS Sensor Accuracy in an IoT-Based Fertigation Prototype Using Polynomial Regression Calibration and Interpolation},
journal = {International Journal of Engineering, Science and Information Technology},
year = {2026},
volume = {6},
number = {1},
pages = {36--43},
doi = {10.52088/ijesty.v6i1.1776}
}
EUVIMED