A Drone-Based Method to Measure Sprint Force-Velocity Profiles in 30-Meter Sprint Test - A Pilot Study
Journal of Sports Science and Medicine · 01.06.2026 · 536-546
DOI: 10.52082/jssm.2026.536 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Sports Science and Medicine, online erschienen am 01.06.2026. Verfasst von Fahui Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Université Lyon 1, LIBM, UR 7424, Villeurbanne, France. Hauptthemen laut MEDLINE: Running, Soccer, Athletic Performance, Exercise Test. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The objective was to determine the test-retest reliability and concurrent validity of a drone system in comparison to a radar device. Seventeen male collegiate soccer players participated in two maximal 30-meter sprint runs. The test-retest reliability of the drone system was evaluated using intraclass correlation coefficients (ICC3,1), coefficient of variation (CV%), and standard error of measurement (SEM). Subsequently, the systematic bias and consistency of the two devices on various force-velocity (F-V) variables (e.g., maximal velocity [Vmax], theoretical maximal velocity [V0], theoretical maximal horizontal force [F0], the slope of the F-V relationship [SFV]) were evaluated using linear mixed model (LMM) and Bland-Altman analysis. The drone system demonstrated moderate to excellent test-retest reliability across all variables (0.59 ≤ ICC ≤ 0.95; CV% < 10%). While LMM analysis detected significant systematic differences for Vmax (p = 0.013) and V0 (p = 0.012), Bland-Altman analysis confirmed high practical agreement with minimal bias (≤ 1.12%) and narrow limits of agreement (LoA < 10%). Pmax, split times (T5m–T20m) and average accelerations (A10m–A20m) demonstrated greater consistency (%Bias ≤ 0.76%) with no significant systematic bias (p > 0.05). Conversely, early-acceleration and model-derived metrics (Tau, Amax, F0, SFV) exhibited significant bias (p ≤ 0.028) and wide LoA exceeding 10% (e.g., F0: -13.37% to 8.56%; SFV: -11.54% to 18.18%). In conclusion, although the drone system exhibits high monitoring value in the maximum speed phase, early-acceleration metrics (Amax, F0, and T5m) should be interpreted with caution for individual-level monitoring. The tracking instability during the early acceleration phase necessitates further algorithm optimization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Université Lyon 1, LIBM, UR 7424, Villeurbanne, France.
- School of Athletic Performance, Shanghai University of Sport, Shanghai, China.
Zitieren
APA
Wang, F., Hautier, C., Song, L., Zhou, Y., Guignard, B., Glaise, P., & Zhang, Q. (2026). A Drone-Based Method to Measure Sprint Force-Velocity Profiles in 30-Meter Sprint Test - A Pilot Study. Journal of Sports Science and Medicine, 536-546. https://doi.org/10.52082/jssm.2026.536
Vancouver
Wang F, Hautier C, Song L, Zhou Y, Guignard B, Glaise P, et al. A Drone-Based Method to Measure Sprint Force-Velocity Profiles in 30-Meter Sprint Test - A Pilot Study. Journal of Sports Science and Medicine. 2026:536-546. doi:10.52082/jssm.2026.536
BibTeX
@article{Wang2026,
author = {Wang, Fahui and Hautier, Christophe and Song, Lin and Zhou, Yong and Guignard, Brice and Glaise, Paul and Zhang, Qingshan},
title = {A Drone-Based Method to Measure Sprint Force-Velocity Profiles in 30-Meter Sprint Test - A Pilot Study},
journal = {Journal of Sports Science and Medicine},
year = {2026},
pages = {536--546},
doi = {10.52082/jssm.2026.536}
}
EUVIMED