EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Assessment of Maximum Oxygen Uptake in Elite Youth Soccer Players: A Comparative Analysis of Smartwatch Technology, Yoyo Intermittent Recovery Test 2, and Respiratory Gas Analysis

Peter Düking, Ludwig Ruf, Stefan Altmann, Maximiliane Thron, Philipp Kunz, Billy Sperlich

Journal of Sports Science and Medicine · 01.06.2024 · 351-357

DOI: 10.52082/jssm.2024.351 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Sports Science and Medicine, online erschienen am 01.06.2024. Verfasst von Peter Düking und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sports Science and Movement Pedagogy, Technische Universität Braunschweig, Braunschweig, Germany. Hauptthemen laut MEDLINE: Soccer, Oxygen Consumption, Exercise Test. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The maximum oxygen uptake (VO2max) is a critical factor for endurance performance in soccer. Novel wearable technology may allow frequent assessment of V̇O2max during non-fatiguing warm-up runs of soccer players with minimal interference to soccer practice. The aim of this study was to assess the validity of VO2max provided by a consumer grade smartwatch (Garmin Forerunner 245, Garmin, Olathe, USA, Software:13.00) and the YoYo Intermittent Recovery Run 2 (YYIR2) by comparing it with respiratory gas analysis. 24 trained male youth soccer players performed different tests to assess VO2max: i) a treadmill test employing respiratory gas analysis, ii) YYIR2 and iii) during a non-fatiguing warm-up run of 10 min wearing a smartwatch as recommended by the device-manufacturer on 3 different days within 2 weeks. As the device-manufacturer indicates that validity of smartwatch-derived VO2max may differ with an increase in runs, 16 players performed a second run with the smartwatch to test this claim. The main evidence revealed that the smartwatch showed an ICC of 0.37 [95% CI: -0.25; 0.71] a mean absolute percentage error (MAPE) of 5.58% after one run, as well as an ICC of 0.54 [95% CI: -0.3; 8.4] and a MAPE of 1.06% after the second run with the smartwatch. The YYIR2 showed an ICC of 0.17 [95% CI: -5.7; 0.6]; and MAPE of 4.2%. When using the smartwatch for VO2max assessment in a non-fatiguing run as a warm-up, as suggested by the device manufacturer before soccer practice, the MAPE diminishes after two runs. Therefore, for more accurate VO2max assessment with the smartwatch, we recommend to perform at least two runs to reduce the MAPE and enhance the validity of the findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SoccerOxygen ConsumptionExercise TestHumansMaleAdolescentRunningWearable Electronic DevicesWarm-Up ExerciseReproducibility of ResultsBreath Tests

Stichwörter der Autor:innen

Data-informed TrainingDigital HealthTechnologyWearableeHealthmHealth

Autor:innen und Institutionen

  • Department of Sports Science and Movement Pedagogy, Technische Universität Braunschweig, Braunschweig, Germany.
  • TSG ResearchLab gGmbH, Zuzenhausen, Germany.
  • Institute of Sports and Sports Science, Karlsruhe Institute of Technology, Karlsruhe, Germany.
  • Integrative and Experimental Exercise Science, Department of Sport Science, University of Würzburg, Würzburg, Germany.

Zitieren

APA

Düking, P., Ruf, L., Altmann, S., Thron, M., Kunz, P., & Sperlich, B. (2024). Assessment of Maximum Oxygen Uptake in Elite Youth Soccer Players: A Comparative Analysis of Smartwatch Technology, Yoyo Intermittent Recovery Test 2, and Respiratory Gas Analysis. Journal of Sports Science and Medicine, 351-357. https://doi.org/10.52082/jssm.2024.351

Vancouver

Düking P, Ruf L, Altmann S, Thron M, Kunz P, Sperlich B. Assessment of Maximum Oxygen Uptake in Elite Youth Soccer Players: A Comparative Analysis of Smartwatch Technology, Yoyo Intermittent Recovery Test 2, and Respiratory Gas Analysis. Journal of Sports Science and Medicine. 2024:351-357. doi:10.52082/jssm.2024.351

BibTeX
@article{Dking2024,
  author = {Düking, Peter and Ruf, Ludwig and Altmann, Stefan and Thron, Maximiliane and Kunz, Philipp and Sperlich, Billy},
  title = {Assessment of Maximum Oxygen Uptake in Elite Youth Soccer Players: A Comparative Analysis of Smartwatch Technology, Yoyo Intermittent Recovery Test 2, and Respiratory Gas Analysis},
  journal = {Journal of Sports Science and Medicine},
  year = {2024},
  pages = {351--357},
  doi = {10.52082/jssm.2024.351}
}
Kostenlos starten →