Estimation of the Aortic Valve Annular Size Measured by Pre-Operative Echocardiogram Validated Against Intra Operative Measurement by Standard Valve Sizers in Patient Undergoing Aortic Valve Replacement Open Heart Surgery
Journal of Bahria University Medical and Dental College · 10.04.2026 · 16 (02) · 627-633
DOI: 10.51985/jbumdc2025837 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bahria University Medical and Dental College, online erschienen am 10.04.2026. Verfasst von Muhammad Aftab Alam Khan.
Abstract (Originalsprache)
t Objective: This study was carried out to determine the diagnostic accuracy of transthoracic echocardiography (TTE) for preoperative sizing of the aortic annulus. It was done by comparing its measurements against the reference standard of direct intraoperative valve sizer measurement in patients who were undergoing surgical aortic valve replacement (SAVR). Methodology: This cross-sectional was conducted at the Department of Cardiac Surgery, Hayatabad Medical Complex, Peshawar. from January 2023 to June 2023. Total 194 consecutive patients who were scheduled for SAVR were enrolled. Preoperative TTE measurements of the aortic annulus were performed in the parasternal long-axis view. The primary outcome was the agreement between TTE and sizer measurements. For this the concordance was defined as a difference of ±1 mm. After data collection the statistical analysis was performed using SPSS version 20.
Results
The mean age of our study population was found to be 66.8 ± 10.5 years, with 63.4% males. The TTE and sizer measurement showed a very strong positive correlation (r = 0.978, p0.05).
Conclusion
The TTE establishes a very strong correlation with direct intraoperative sizing, but it also exhibits a consistent underestimation bias
Zitieren
APA
Khan, M. A. A. (2026). Estimation of the Aortic Valve Annular Size Measured by Pre-Operative Echocardiogram Validated Against Intra Operative Measurement by Standard Valve Sizers in Patient Undergoing Aortic Valve Replacement Open Heart Surgery. Journal of Bahria University Medical and Dental College, 16(02), 627-633. https://doi.org/10.51985/jbumdc2025837
Vancouver
Khan MAA. Estimation of the Aortic Valve Annular Size Measured by Pre-Operative Echocardiogram Validated Against Intra Operative Measurement by Standard Valve Sizers in Patient Undergoing Aortic Valve Replacement Open Heart Surgery. Journal of Bahria University Medical and Dental College. 2026;16(02):627-633. doi:10.51985/jbumdc2025837
BibTeX
@article{Khan2026,
author = {Khan, Muhammad Aftab Alam},
title = {Estimation of the Aortic Valve Annular Size Measured by Pre-Operative Echocardiogram Validated Against Intra Operative Measurement by Standard Valve Sizers in Patient Undergoing Aortic Valve Replacement Open Heart Surgery},
journal = {Journal of Bahria University Medical and Dental College},
year = {2026},
volume = {16},
number = {02},
pages = {627--633},
doi = {10.51985/jbumdc2025837}
}
EUVIMED