EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Uncertainty-Aware Medical Vision–Language Classification on a Lightweight MedMNIST-Compatible Biomedical Patch Benchmark

Shenghan Lu, Tracey Zou

Journal of Technology Informatics and Engineering · 13.06.2026 · 5 (2) · 01-19

DOI: 10.51903/jtie.v5i2.530 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Technology Informatics and Engineering, online erschienen am 13.06.2026. Verfasst von Shenghan Lu und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Medical image classifiers can be accurate while still being unsafe to use when their confidence values are poorly calibrated or when their predictions are communicated in language that overstates diagnostic certainty. This paper presents an uncertainty-aware medical vision-language classification workflow for lightweight 28×28 biomedical images. The target setting is MedMNIST-style classification, where images are standardized to small spatial sizes and where compact CNN, residual, and transformer models can be trained on ordinary hardware. The official MedMNIST v2 collection contains 12 two-dimensional and 6 three-dimensional biomedical image subsets; however, the execution environment used for this manuscript could read the official documentation but could not fetch binary Zenodo files. Three lightweight models were trained and evaluated across three random seeds: a 53,380-parameter CNN, a 392,092-parameter tiny residual network, and a 77,956-parameter tiny Vision Transformer. Each model used the same 2,240/320/640 train/validation/test split, AdamW optimization, and validation-set temperature scaling. The evaluated metrics were top-1 accuracy, macro one-vs-rest ROC-AUC, negative log likelihood, multiclass Brier score, expected calibration error, predictive entropy, and confusion-matrix/class-level metrics. TinyViT achieved the highest mean calibrated top-1 accuracy, 0.9906 ± 0.0016, while SmallCNN achieved the best mean macro ROC-AUC, 0.9993 ± 0.0005, and the best mean post-calibration ECE, 0.0115 ± 0.0028. Temperature scaling reduced ECE for all models, with reductions of 0.1153 for SmallCNN, 0.0853 for TinyResNet, and 0.1189 for TinyViT. A deterministic language-card module converted calibrated predictions into patient-friendly decision-support text that explicitly includes confidence, uncertainty, visual cue wording, and a non-diagnostic safety caveat.

Zitieren

APA

Lu, S., & Zou, T. (2026). Uncertainty-Aware Medical Vision–Language Classification on a Lightweight MedMNIST-Compatible Biomedical Patch Benchmark. Journal of Technology Informatics and Engineering, 5(2), 01-19. https://doi.org/10.51903/jtie.v5i2.530

Vancouver

Lu S, Zou T. Uncertainty-Aware Medical Vision–Language Classification on a Lightweight MedMNIST-Compatible Biomedical Patch Benchmark. Journal of Technology Informatics and Engineering. 2026;5(2):01-19. doi:10.51903/jtie.v5i2.530

BibTeX
@article{Lu2026,
  author = {Lu, Shenghan and Zou, Tracey},
  title = {Uncertainty-Aware Medical Vision–Language Classification on a Lightweight MedMNIST-Compatible Biomedical Patch Benchmark},
  journal = {Journal of Technology Informatics and Engineering},
  year = {2026},
  volume = {5},
  number = {2},
  pages = {01--19},
  doi = {10.51903/jtie.v5i2.530}
}
Kostenlos starten →