A TMAH-Chloroform Sample-Preparation Workflow for Nile Red-Based Screening of Microplastics in Animal Feed
Journal of Animal Science and Technology · 13.11.2026
DOI: 10.5187/jast.2600254 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Animal Science and Technology, online erschienen am 13.11.2026. Verfasst von Veysel Doğan.
Abstract (Originalsprache)
Animal feed is increasingly recognized as an important route of microplastic (MP) exposure in livestock production systems; however, reliable fluorescence-based detection remains challenging because proteins, lipids, pigments, and other organic constituents interfere with fluorescence analyses. This study developed and evaluated a sample-preparation protocol combining tetramethylammonium hydroxide (TMAH) digestion with chloroform (TCM) extraction to reduce matrix interference while preserving the fluorescence characteristics of MP particles prior to Nile Red (NR) staining. The protocol was evaluated using five commercially available animal feeds (layer, broiler, calf starter, calf grower, and turkey feeds) and four representative polymers: polyethylene (PE), polypropylene (PP), polystyrene (PS), and polyethylene terephthalate (PET). Fluorescence microscopy, quantitative fluorescence intensity measurement, linear regression analysis, and discriminant function analysis were used to assess the analytical performance of the proposed workflow. The evaluated protocol reduced matrix-derived fluorescence interference and enabled clear visualization of NR-positive particles without significantly altering the fluorescence responses of the reference polymers. Among the tested polymers, PS exhibited the highest fluorescence intensity (174.69 ± 20.91), followed by PP (143.21 ± 37.74), PE (134.03 ± 38.36), and PET (117.59 ± 36.93). Significant differences in fluorescence intensity were observed among polymer types (p < 0.05), and discriminant function analysis demonstrated that fluorescence intensity can serve as a complementary analytical parameter for polymer differentiation, although classification accuracy remained moderate (47%). Collectively, the proposed TMAH-TCM workflow provides a practical sample-preparation approach for NR-based screening of MP in animal feed matrices, while fluorescence intensity may provide complementary information for preliminary polymer differentiation.
Zitieren
APA
Doğan, V. (2026). A TMAH-Chloroform Sample-Preparation Workflow for Nile Red-Based Screening of Microplastics in Animal Feed. Journal of Animal Science and Technology. https://doi.org/10.5187/jast.2600254
Vancouver
Doğan V. A TMAH-Chloroform Sample-Preparation Workflow for Nile Red-Based Screening of Microplastics in Animal Feed. Journal of Animal Science and Technology. 2026. doi:10.5187/jast.2600254
BibTeX
@article{Doan2026,
author = {Doğan, Veysel},
title = {A TMAH-Chloroform Sample-Preparation Workflow for Nile Red-Based Screening of Microplastics in Animal Feed},
journal = {Journal of Animal Science and Technology},
year = {2026},
doi = {10.5187/jast.2600254}
}