EUVIMEDEUVIMED entdecken
Crossref

General Purpose Deep Learning Attenuation Correction Improves Diagnostic Accuracy of SPECT MPI: A Multicenter Study

Shanbhag, Aakash D, Miller, Robert J H, Lemley, Mark, Kavanagh, Paul, Liang, Joanna X, Marcinkiewicz, Anna M und 26 weitere

Zurich Open Repository and Archive (University of Zurich) · 16.01.2026

DOI: 10.5167/uzh-282858 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Zurich Open Repository and Archive (University of Zurich), erschienen am 16.01.2026. Verfasst von Shanbhag und 37 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) uses computed tomography (CT)-based attenuation correction (AC) to improve diagnostic accuracy. Deep learning (DL) has the potential to generate synthetic AC images, as an alternative to CT-based AC.

Objectives

This study evaluated whether DL-generated synthetic SPECT images could enhance accuracy of conventional SPECT MPI.

Methods

Study investigators developed a DL model in a multicenter cohort of 4,894 patients from 4 sites to generate simulated SPECT AC images (DeepAC). The model was externally validated in 746 patients from 72 sites in a clinical trial (A Phase 3 Multicenter Study to Assess PET Imaging of Flurpiridaz F 18 Injection in Patients With CAD; NCT01347710) and in 320 patients from another external site. In the first external cohort, the study assessed the diagnostic accuracy for obstructive coronary artery disease (CAD)-defined as left main coronary artery stenosis ≥50% or ≥70% in other vessels-for total perfusion deficit (TPD). In the latter, the study completed change analysis and compared quantitative scores for AC, DeepAC, and nonattenuation correction (NC) with clinical scores.

Conclusions

In a multicenter external cohort, DeepAC improved prediction performance for obstructive CAD. This approach could enhance diagnostic accuracy in facilities using conventional SPECT systems without requiring additional equipment, imaging time, or radiation exposure.

Schlagwörter

SPECTartificial intelligenceattenuation correctiondeep learningmyocardial perfusion imaging

Zitieren

APA

Shanbhag, D, A., Miller, H, R. J., Lemley, Mark, Kavanagh, Paul, Liang, X, J., Marcinkiewicz, M, A., Builoff, Valerie, Kriekinge, V., Serge, Ruddy, D, T., Fish, …, & J, P. (2026). General Purpose Deep Learning Attenuation Correction Improves Diagnostic Accuracy of SPECT MPI: A Multicenter Study. Zurich Open Repository and Archive (University of Zurich). https://doi.org/10.5167/uzh-282858

Vancouver

Shanbhag, D A, Miller, H RJ, Lemley, Mark, et al. General Purpose Deep Learning Attenuation Correction Improves Diagnostic Accuracy of SPECT MPI: A Multicenter Study. Zurich Open Repository and Archive (University of Zurich). 2026. doi:10.5167/uzh-282858

BibTeX
@article{Shanbhag2026,
  author = {Shanbhag and D, Aakash and Miller and H, Robert J and Lemley and Mark and Kavanagh and Paul and Liang and X, Joanna and Marcinkiewicz and M, Anna and Builoff and Valerie and Kriekinge, Van and Serge and Ruddy and D, Terrence and Fish and B, Mathews and Einstein and J, Andrew and Martins and Monica and Halcox and P, Julian and Kaufmann and A, Philipp and Buckley and Christopher and Bateman and M, Timothy and Berman and S, Daniel and Dey and Damini and Slomka and J, Piotr},
  title = {General Purpose Deep Learning Attenuation Correction Improves Diagnostic Accuracy of SPECT MPI: A Multicenter Study},
  journal = {Zurich Open Repository and Archive (University of Zurich)},
  year = {2026},
  doi = {10.5167/uzh-282858}
}
Kostenlos starten →