Splenic Switch-Off in 3D Adenosine Stress CMR Perfusion for Differentiating False-Negative from True-Negative Studies Identified by FFR
Zurich Open Repository and Archive (University of Zurich) · 03.10.2025
DOI: 10.5167/uzh-279852 ↗Kurz gefasst
Fachartikel in der Zeitschrift Zurich Open Repository and Archive (University of Zurich), erschienen am 03.10.2025. Verfasst von Károlyi und 27 weiteren Autor:innen.
Abstract (Originalsprache)
False-negative cardiac magnetic resonance (CMR) perfusion results may arise from inadequate stress responses, even when patients exhibit an adequate clinical or heart-rate response to adenosine. This study aimed to explore the ability of qualitative and quantitative splenic switch-off markers to differentiate false-negative from true-negative adenosine stress-perfusion CMR findings, in a cohort where fractional flow reserve (FFR) was used to adjudicate lesion significance. Patients with known or suspected coronary artery disease (CAD) from five centers underwent 3D adenosine stress perfusion CMR and coronary angiography with FFR. Splenic switch-off was assessed qualitatively using both standard stress-to-rest (SSO) and a stress-only (SSO) approach. In addition, quantitative signal intensity (SI) ratios were assessed, including the splenic stress-to-rest SI-ratio (SI) and the spleen-to-myocardium SI ratio at stress (SI). The diagnostic accuracy of these measures was evaluated using cross-validated area under the curve (cvAUC) analysis. Among 179 patients (mean age 63 ± 10 years; 130 male), SSO prevalence was 73% and was significantly more frequent in true-negative than false-negative CMR cases (80.6% vs. 36.8%, p
Schlagwörter
Zitieren
APA
Károlyi, Mihály, Fuetterer, Maximilian, Kolossváry, Márton, Wilzeck, C, V., Plein, Sven, Biondo, Andrea, Gotschy, Alexander, Frick, Michael, Gebker, Rolf, Alkadhi, …, & Robert (2025). Splenic Switch-Off in 3D Adenosine Stress CMR Perfusion for Differentiating False-Negative from True-Negative Studies Identified by FFR. Zurich Open Repository and Archive (University of Zurich). https://doi.org/10.5167/uzh-279852
Vancouver
Károlyi, Mihály, Fuetterer, Maximilian, Kolossváry, Márton, et al. Splenic Switch-Off in 3D Adenosine Stress CMR Perfusion for Differentiating False-Negative from True-Negative Studies Identified by FFR. Zurich Open Repository and Archive (University of Zurich). 2025. doi:10.5167/uzh-279852
BibTeX
@article{Krolyi2025,
author = {Károlyi and Mihály and Fuetterer and Maximilian and Kolossváry and Márton and Wilzeck and C, Verena and Plein and Sven and Biondo and Andrea and Gotschy and Alexander and Frick and Michael and Gebker and Rolf and Alkadhi and Hatem and Paetsch and Ingo and Jahnke and Cosima and Kozerke and Sebastian and Manka and Robert},
title = {Splenic Switch-Off in 3D Adenosine Stress CMR Perfusion for Differentiating False-Negative from True-Negative Studies Identified by FFR},
journal = {Zurich Open Repository and Archive (University of Zurich)},
year = {2025},
doi = {10.5167/uzh-279852}
}
EUVIMED