Exchange rates of second generation Microcuff® pediatric endotracheal tubes in children weighing more than 3 kg : A retrospective audit
Zurich Open Repository and Archive (University of Zurich) · 24.01.2025
DOI: 10.5167/uzh-269576 ↗Kurz gefasst
Fachartikel in der Zeitschrift Zurich Open Repository and Archive (University of Zurich), erschienen am 24.01.2025. Verfasst von Schmidt-Deubig und 13 weiteren Autor:innen.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Background
Cuffed endotracheal tubes (cETT) pose the potential advantage of an infrequent need for reintubation in pediatric patients compared to uncuffed tubes. The aim of this study was to investigate tube exchange rates using second generation Microcuff® pediatric endotracheal tubes (PET) with an adapted sizing recommendation in a large single institution cohort of children and to identify potential variables associated with an elevated risk of tube exchange.
Methods
Patient data obtained from the electronic patient data management system of the Department of Anesthesia, University Children’s Hospital Zurich, Switzerland, were retrospectively assessed for demographic and anthropometric information, size of the internal tube diameter used for positive pressure ventilation and divergence from the size recommendation chart.
Results
Data from 14,188 children younger than 16 years (median 5.3 years) and weighing at least 3 kg who underwent oral or nasal tracheal intubation using second generation Microcuff® PET between 2009 and 2015 were included. Of 13,219 oral tracheal intubations 12,049 (84.9%) were performed according to the manufacturer’s size recommendation and 1170 with divergent endotracheal tubes. The odds ratio (OR) of oral reintubation was 0.13% (95% confidence interval 0.08–0.22%) for cases using the manufacture’s size recommendation correctly and 22.74% (95% confidence interval 20.42–25.23%) for patients intubated with a not recommended tube (p < 0.0001).
Conclusion
These findings indicate that the second generation Microcuff® PETs can be reliably used with low tube exchange rates across the entire pediatric age range when the tube size is selected according to the manufacturer’s size recommendation chart. Adherence to the manufacturer’s tube size recommendation is urgently advised.
Schlagwörter
Zitieren
APA
Schmidt-Deubig, Ilka, Kemper, Michael, Wendel-Garcia, D, P., Weiss, Markus, Thomas, Jörg, Both, P, C., Schmitz, & Achim (2025). Exchange rates of second generation Microcuff® pediatric endotracheal tubes in children weighing more than 3 kg : A retrospective audit. Zurich Open Repository and Archive (University of Zurich). https://doi.org/10.5167/uzh-269576
Vancouver
Schmidt-Deubig, Ilka, Kemper, Michael, Wendel-Garcia, D P, et al. Exchange rates of second generation Microcuff® pediatric endotracheal tubes in children weighing more than 3 kg : A retrospective audit. Zurich Open Repository and Archive (University of Zurich). 2025. doi:10.5167/uzh-269576
BibTeX
@article{SchmidtDeubig2025,
author = {Schmidt-Deubig and Ilka and Kemper and Michael and Wendel-Garcia and D, Pedro and Weiss and Markus and Thomas and Jörg and Both and P, Christian and Schmitz and Achim},
title = {Exchange rates of second generation Microcuff® pediatric endotracheal tubes in children weighing more than 3 kg : A retrospective audit},
journal = {Zurich Open Repository and Archive (University of Zurich)},
year = {2025},
doi = {10.5167/uzh-269576}
}
EUVIMED