Lead Integrity and Failure Evaluation in Left Bundle Branch Area Pacing (LIFE-LBBAP) Study
Zurich Open Repository and Archive (University of Zurich) · 08.01.2025
DOI: 10.5167/uzh-267574 ↗Kurz gefasst
Fachartikel in der Zeitschrift Zurich Open Repository and Archive (University of Zurich), erschienen am 08.01.2025. Verfasst von De Pooter und 45 weiteren Autor:innen.
Abstract (Originalsprache)
BACKGROUND Left bundle branch area pacing (LBBAP) has gained increased adoption globally with the use of both lumenless leads (LLLs) and stylet-driven leads (SDLs). As these leads have been developed for conventional endocardial pacing sites, concerns remain regarding the lead integrity with LBBAP. OBJECTIVES This study evaluates lead integrity of pacing leads used for LBBAP in a large, real-world cohort of patients with LBBAP. METHODS Patients with successful LBBAP from 17 international centers were enrolled in this observational study. Data on overall lead integrity, fracture rates, and locations of fractures were collected. RESULT The study enrolled 8,255 patients with LBBAP (age 73 ± 13 years, 42% female, 68% LLLs, and 32% SDLs). Overall lead survival rate was 99.7% with median follow-up of 16.4 (Q1-Q3: 6.4-28.8) months. Lead fracture occurred in 12 of 8,255 (0.15%) patients. Lead fracture rates of LLLs occurred in 2 of 5,609 (0.04%) vs 10 of 2,646 (0.4%) patients for SDLs, during a follow-up of 19.5 (Q1-Q3: 9.7-33) and 10.3 (Q1-Q3: 2.9-19.7) months, respectively (P < 0.001). SDL fractures occurred at 13.9 (Q1-Q3: 6.1-17.7) months after implant, whereas 2 LLL fractures occurred at 21 and 31.4 months. SDL and LLL conductor fractures were observed in 7 of 17 and 2 of 17 centers, respectively. Confirmed fractures of the SDL lead originated within the interelectrode lead segment, whereas LLL fractures occurred proximal to the ring. CONCLUSIONS LBBAP lead performance of LLLs and SDLs is high at midterm follow-up. SDLs exhibit higher rates of fracture compared to LLLs. Hot spots for conductor fracture are the distal interelectrode segment in SDLs and the segment proximal to the ring electrode in LLLs.
Schlagwörter
Zitieren
APA
Pooter, D., Jan, Breitenstein, Alexander, Özpak, Emine, Haeberlin, Andreas, Hofer, Daniel, Waroux, L. P. D., Jean-Benoit, Wauters, Aurélien, Kim, Tae-Hoon, Lee, So-Ryoung, Park, …, & Haran (2025). Lead Integrity and Failure Evaluation in Left Bundle Branch Area Pacing (LIFE-LBBAP) Study. Zurich Open Repository and Archive (University of Zurich). https://doi.org/10.5167/uzh-267574
Vancouver
Pooter D, Jan, Breitenstein, Alexander, Özpak, Emine, et al. Lead Integrity and Failure Evaluation in Left Bundle Branch Area Pacing (LIFE-LBBAP) Study. Zurich Open Repository and Archive (University of Zurich). 2025. doi:10.5167/uzh-267574
BibTeX
@article{Pooter2025,
author = {Pooter, De and Jan and Breitenstein and Alexander and Özpak and Emine and Haeberlin and Andreas and Hofer and Daniel and Waroux, Le Polain de and Jean-Benoit and Wauters and Aurélien and Kim and Tae-Hoon and Lee and So-Ryoung and Park and Jun, Young and Gobitz and Michael and Kiełbasa and Grzegorz and Zalavadia and Dipen and Tolppanen and Heli and Žižek and David and Zanon and Francesco and Marcantoni and Lina and Ponnusamy, Sundaram and Shunmuga and Karvonen and Jarkko and Cano and Oscar and Jastrzebski and Marek and Vijayaraman and Pugazhendhi and Burri and Haran},
title = {Lead Integrity and Failure Evaluation in Left Bundle Branch Area Pacing (LIFE-LBBAP) Study},
journal = {Zurich Open Repository and Archive (University of Zurich)},
year = {2025},
doi = {10.5167/uzh-267574}
}
EUVIMED