Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat achilles tendon biomechanics
Acta Orthopaedica et Traumatologica Turcica · 30.10.2026 · 60 (6)
DOI: 10.5152/j.aott.2026.25749 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Orthopaedica et Traumatologica Turcica, online erschienen am 30.10.2026. Verfasst von Lu Zhang und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Objective
This study aimed to evaluate the effects of different preservation methods, including −20°C freezing, −80°C freezing, liquid nitrogen, and 10% formaldehyde preservation, on the biomechanical properties of rat Achilles tendons.
Methods
This experimental biomechanical study included Achilles tendons obtained from 25 male Sprague–Dawley rats (age, 3 months; weight, 220–280 g). The rats were randomly allocated to five groups (n = 5 each): fresh, −20°C freezing, −80°C freezing, liquid nitrogen preservation, and 10% formaldehyde preservation. Specimens in the preservation groups were stored for 1 week before biomechanical testing. Following preconditioning, the tendons were subjected to axial tensile loading at 3 mm/min until failure. Cross-sectional area, maximum elongation, maximum strain, maximum stress, maximum load, and stiffness were evaluated.
Results
Initial tendon length did not differ among the 5 groups (P = .92). Maximum load was comparable between the fresh (48.78 ± 2.35 N), −20°C (50.28 ± 2.57 N), and −80°C (48.95 ± 3.21 N) groups, whereas it was significantly lower in the liquid nitrogen (34.21 ± 2.98 N) and 10% formaldehyde (23.55 ± 2.39 N) groups (P < .05). Stiffness was significantly higher in the −20°C (32.99 ± 2.37 N/mm) and −80°C (30.74 ± 1.63 N/mm) groups than in the fresh (25.80 ± 1.11 N/mm), liquid nitrogen (23.21 ± 1.27 N/mm), and 10% formaldehyde (19.66 ± 1.36 N/mm) groups (P < .05). The 10% formaldehyde group also showed significantly lower maximum elongation, maximum strain, and maximum stress than the cryopreservation groups (P < .05).
Conclusion
Preservation at −20°C and −80°C maintained maximum tendon load at levels comparable to fresh tendons but resulted in increased stiffness. Liquid nitrogen and 10% formaldehyde preservation were associated with lower maximum load, with the most pronounced alterations observed after formaldehyde preservation. These findings indicate that the choice of preservation method should be considered when interpreting biomechanical tendon studies, as different preservation methods may affect individual biomechanical parameters differently. Cite this article as: Zhang L, Wang J, Hou W, Wang L. Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat Achilles tendon biomechanics. Acta Orthop Traumatol Turc., 2026; 60(6), 0749, doi:10.5152/j.aott.2026.25749.
Zitieren
APA
Zhang, L., Wang, J., Hou, W., & Wang, L. (2026). Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat achilles tendon biomechanics. Acta Orthopaedica et Traumatologica Turcica, 60(6). https://doi.org/10.5152/j.aott.2026.25749
Vancouver
Zhang L, Wang J, Hou W, Wang L. Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat achilles tendon biomechanics. Acta Orthopaedica et Traumatologica Turcica. 2026;60(6). doi:10.5152/j.aott.2026.25749
BibTeX
@article{Zhang2026,
author = {Zhang, Lu and Wang, Jie and Hou, Wenbo and Wang, Lei},
title = {Effects of freezing, liquid nitrogen, and formaldehyde preservation on rat achilles tendon biomechanics},
journal = {Acta Orthopaedica et Traumatologica Turcica},
year = {2026},
volume = {60},
number = {6},
doi = {10.5152/j.aott.2026.25749}
}
EUVIMED