Off-label use of a PHILOS plate in tibiotalocalcaneal arthrodesis with variable medial cannulated screw support: a retrospective evaluation of 32 ankles
Acta Orthopaedica et Traumatologica Turcica · 08.07.2026 · 60 (4)
DOI: 10.5152/j.aott.2026.25553 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Orthopaedica et Traumatologica Turcica, online erschienen am 08.07.2026. Verfasst von Ahmet Yurteri und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Konya City Hospital, Konya, Türkiye. Hauptthemen laut MEDLINE: Arthrodesis, Bone Plates, Bone Screws, Ankle Joint. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
To evaluate the clinical and radiographic outcomes of tibiotalocalcaneal (TTC) arthrodesis performed using a lateral transfibular approach with the off-label application of a Proximal Humerus Internal Locking System (PHILOS) plate and to exploratorily assess outcomes according to the use of supplemental medial cannulated screw fixation.
Methods
Thirty patients (32 ankles) who underwent TTC arthrodesis between January 2019 and June 2024 and had ≥12 months of followup were retrospectively reviewed. Demographics, comorbidities, surgical indications, implant configuration, fusion rates, complications, reoperations, and patient satisfaction were analyzed. Subgroup findings regarding medial screw support were evaluated descriptively.
Results
The mean follow-up duration was 37.3 ± 19.2 months, and fusion was achieved in 90.6% (29/32) of ankles. Complications occurred in 18.8% (6/32), including 3 nonunions, 2 peri-implant tibial fractures, and 1 superficial infection. Reoperation was required in 3 ankles (9.4%). Patient-reported satisfaction was “excellent” in 71.9%, “good” in 12.5%, “fair” in 6.3%, and “poor” in 9.4%.
Conclusion
Tibiotalocalcaneal arthrodesis performed using the PHILOS plate with a lateral approach demonstrated acceptable fusion and complication rates in this cohort. Subgroup observations regarding supplemental medial screw fixation should be interpreted as exploratory and hypothesis generating. Cite this article as: Yurteri A, Mercan N, Kekeç AF, Tahak F, Yıldırım A. Off-label use of a PHILOS plate in tibiotalocalcaneal arthrodesis with variable medial cannulated screw support: a retrospective evaluation of 32 ankles. Acta Orthop Traumatol Turc.2026; 60(4), 0553, doi: 10.5152/j.aott.2026.25553.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopaedics and Traumatology, Konya City Hospital, Konya, Türkiye.
- Department of Orthopaedics and Traumatology, Kahramanmaraş Necip Fazıl City Hospital, Kahramanmaraş, Türkiye.
- Department of Orthopaedics and Traumatology, Necmettin Erbakan University Faculty of Medicine, Konya, Türkiye.
- Department of Orthopaedics and Traumatology, Karapınar State Hospital, Konya, Türkiye.
- Department of Orthopaedics and Traumatology, Health Application and Research Center, Konya City Hospital, University of Health Sciences, Konya, Türkiye.
Zitieren
APA
Yurteri, A., Mercan, N., Kekeç, A. F., Tahak, F., & Yıldırım, A. (2026). Off-label use of a PHILOS plate in tibiotalocalcaneal arthrodesis with variable medial cannulated screw support: a retrospective evaluation of 32 ankles. Acta Orthopaedica et Traumatologica Turcica, 60(4). https://doi.org/10.5152/j.aott.2026.25553
Vancouver
Yurteri A, Mercan N, Kekeç AF, Tahak F, Yıldırım A. Off-label use of a PHILOS plate in tibiotalocalcaneal arthrodesis with variable medial cannulated screw support: a retrospective evaluation of 32 ankles. Acta Orthopaedica et Traumatologica Turcica. 2026;60(4). doi:10.5152/j.aott.2026.25553
BibTeX
@article{Yurteri2026,
author = {Yurteri, Ahmet and Mercan, Numan and Kekeç, Ahmet Fevzi and Tahak, Fatih and Yıldırım, Ahmet},
title = {Off-label use of a PHILOS plate in tibiotalocalcaneal arthrodesis with variable medial cannulated screw support: a retrospective evaluation of 32 ankles},
journal = {Acta Orthopaedica et Traumatologica Turcica},
year = {2026},
volume = {60},
number = {4},
doi = {10.5152/j.aott.2026.25553}
}
EUVIMED