Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther
Acta Orthopaedica et Traumatologica Turcica · 26.02.2026 · 60 (1)
DOI: 10.5152/j.aott.2026.25268 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Orthopaedica et Traumatologica Turcica, online erschienen am 26.02.2026. Verfasst von Abdurrahman Yılmaz und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Türkiye. Hauptthemen laut MEDLINE: Software, Pelvic Bones, Radiography, Radiographic Image Interpretation, Computer-Assisted. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
The anteroposterior (AP) pelvic X-ray is commonly used for assessing conditions affecting the bony pelvis. The objective of this study was to develop new pelvic X-ray assessment software (CalculOrther) to assess AP pelvic X-rays and evaluate its reliability.
Methods
CalculOrther was developed in 4 stages. Initially, a dataset comprising pelvic X-rays was generated. During the second stage, the convolutional neural network model was trained to identify anatomical landmarks in the pelvic X-ray images. The Hough transform was used to locate the circle and center of the femoral head in the third stage. The border pixels were generated using mathematical morphological processes, and the requisite angles were measured in the fourth stage. Then manual measurements and the software developed were analyzed with Pearson’s correlation and intraobserver and interobserver correlation coefficients. Subsequently, the mean error and the root mean square error (RMSE) were acquired.
Results
The Pearson’s correlation coefficients varied from 0.84 to 0.99 (P < .001). The interobserver and intraobserver correlation coefficients ranged from 0.77 to 0.99 and from 0.75 to 0.94, respectively. The RMSE ranged from 0.31 to 4.38 and the mean error from 0.05 to 2.86. The mean duration for manual measurements was 230 (177-284) seconds and 215 (160-255) seconds, respectively. The software required an average time of 3.18 (2.95-3.52) seconds to make the same measurements.
Conclusion
Regarding femoroacetabular impingement and hip dysplasia, artificial intelligence can analyze pelvic radiographs and generate equally accurate results within a shorter duration compared to traditional measuring methods. Cite this article as: Yilmaz A, Selcuk T, Aksoy T, Atilla B. Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther. Acta Orthop Traumatol Turc., 2026; 60(1), 0268, doi: 10.5152/j.aott.2026.25268
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Türkiye.
- Department of Electrical & Electronics Engineering, Kahramanmaraş Sütçü İmam University, Türkiye.
- University of Miami, Florida, United States.
Zitieren
APA
Yılmaz, A., Selçuk, T., Aksoy, T., & Atilla, B. (2026). Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther. Acta Orthopaedica et Traumatologica Turcica, 60(1). https://doi.org/10.5152/j.aott.2026.25268
Vancouver
Yılmaz A, Selçuk T, Aksoy T, Atilla B. Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther. Acta Orthopaedica et Traumatologica Turcica. 2026;60(1). doi:10.5152/j.aott.2026.25268
BibTeX
@article{Ylmaz2026,
author = {Yılmaz, Abdurrahman and Selçuk, Turab and Aksoy, Taha and Atilla, Bülent},
title = {Evaluation of the reliability of novel pelvic X-ray assessment software: CalculOrther},
journal = {Acta Orthopaedica et Traumatologica Turcica},
year = {2026},
volume = {60},
number = {1},
doi = {10.5152/j.aott.2026.25268}
}
EUVIMED