Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique
Acta Orthopaedica et Traumatologica Turcica · 2025
DOI: 10.5152/j.aott.2025.24077 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Acta Orthopaedica et Traumatologica Turcica, 2025. Verfasst von Hakan Eskara und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Sancaktepe Sehit Prof. Dr. Ilhan Varank Training and Research Hospital, Istanbul, Türkiye. Hauptthemen laut MEDLINE: Rotator Cuff Injuries, Suture Techniques, Osteoporosis, Rotator Cuff. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
This study aimed to compare the biomechanical characteristics of conventional transosseous equivalent (TOE) techniqueswith those of the novel free independent double-row medial fixation method, using rigid polyurethane (PU) foam blocks to simulateosteoporotic humerus bone.
Methods
In this biomechanical study, 4 groups were tested using rigid PU foam blocks with osteoporotic properties and bovine infraspinatus tendons to simulate the rotator cu!. Groups 1 and 2 employed conventional TOE techniques: medial row knotted repair and knotless repair, respectively. Groups 3 and 4 utilized the “free independent double-row medial fixation method,” di!ering in the order of suture tying. Several biomechanical characteristic and pressure parameters were measured.
Results
Groups 3 (0.16 ± 0.04 MPa) and 4 (0.17 ± 0.05 MPa) achieved significantly higher initial contact pressure compared to standard TOE techniques (P=.039). While contact area (Group 3: 102.4 ± 55.0 mm", Group 4: 110.4 ± 37.2 mm") and ultimate failure force (Group 3: 212.0 ± 26.5 N, Group 4: 214.7 ± 30.2 N) were relatively higher, the di!erences were not statistically significant (P=.135 and P=.3, respectively). The overall failure types included medial anchor pullout (40%) and suture/tendon stripping (32.5%), with no significant di!erences among groups (P=.260).
Conclusion
With superior contact pressure and comparable ultimate failure and contact area measurements, the novel independent double-row medial fixation technique may be a viable alternative to conventional TOE techniques for enhancing medial row stability in osteoporotic conditions. Cite this article as: Eskara H, Keskin A, Tatar Y, Gercek N, Imren Y, Semih Dedeoglu S. Biomechanical comparison of rotator cu! repair techniques in osteoporoticconditions: testing a novel technique. Acta Orthop Traumatol Turc., 2025;59(2):79-85.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopedics and Traumatology, Sancaktepe Sehit Prof. Dr. Ilhan Varank Training and Research Hospital, Istanbul, Türkiye.
- Department of Orthopedics and Traumatology, Metin Sabanci Baltalimani Bone Diseases Training and Research Hospital, Istanbul, Türkiye.
- Department of Sport Health Sciences Marmara University Faculty of Sport Sciences, Istanbul, Türkiye.
- Department of Orthopedics and Traumatology, Istinye University School of Medicine, Liv Hospital Vadistanbul, Istanbul, Türkiye.
Zitieren
APA
Eskara, H., Keskin, A., Tatar, Y., Gercek, N., Imren, Y., & Dedeoglu, S. S. (2025). Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique. Acta Orthopaedica et Traumatologica Turcica. https://doi.org/10.5152/j.aott.2025.24077
Vancouver
Eskara H, Keskin A, Tatar Y, Gercek N, Imren Y, Dedeoglu SS. Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique. Acta Orthopaedica et Traumatologica Turcica. 2025. doi:10.5152/j.aott.2025.24077
BibTeX
@article{Eskara2025,
author = {Eskara, Hakan and Keskin, Ahmet and Tatar, Yasar and Gercek, Nejla and Imren, Yunus and Dedeoglu, Suleyman Semih},
title = {Biomechanical comparison of rotator cuff repair techniques in osteoporotic conditions: testing a novel technique},
journal = {Acta Orthopaedica et Traumatologica Turcica},
year = {2025},
doi = {10.5152/j.aott.2025.24077}
}
EUVIMED