Test-Retest Reliability, Effects of Age and Comparison of Horizontal 2 Semicircular Canals Gain Values between Head Impulse and Suppression Head Impulse Paradigms
The Journal of International Advanced Otology · 13.01.2023 · 19 (1) · 33-40
DOI: 10.5152/iao.2023.21387 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of International Advanced Otology, online erschienen am 13.01.2023. Verfasst von Sharifah Zainon Sayed und 4 weiteren Autor:innen. Beteiligte Einrichtung: Audiology Programme, Centre for Rehabilitation and Special Needs Studies (iCaRehab), Universiti Kebangsaan Malaysia Faculty of Health Sciences, Kuala…. Hauptthemen laut MEDLINE: Reflex, Vestibulo-Ocular, Semicircular Canals. Die Arbeit wurde bisher 7-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
BACKGROUND: This study investigates the test-retest reliability, aging effects, and differences in horizontal semicircular canals gain values between the head impulse paradigm and suppression head impulse paradigm. METHODS: Sixty healthy adult subjects aged 22-76-year-old (mean ± standard deviation=47.27 ± 18.29) participated in the head impulse paradigm and suppression head impulse paradigm using the video head impulse test. The Head impulse paradigm was used to assess all 6 semicircular canals, while suppression head impulse paradigm measured only the horizontal canals. Twenty subjects aged 22-40-year-old (25.25 ± 4.9) underwent a second session for the test-retest reliability. RESULTS: There were good test-retest reliability for both measures (right horizontal head impulse paradigm, intraclass correlation coefficient=0.80; left horizontal head impulse paradigm, intraclass correlation coefficient=0.77; right anterior head impulse paradigm, intraclass correlation coefficient=0.86; left anterior head impulse paradigm, intraclass correlation coefficient=0.78; right posterior head impulse paradigm, intraclass correlation coefficient=0.78; left posterior head impulse paradigm, intraclass correlation coefficient=0.75; right horizontal suppression head impulse paradigm, intraclass correlation coefficient=0.76; left horizontal suppression head impulse paradigm, intraclass correlation coefficient=0.79). The test-retest reliability for suppression head impulse paradigmanti-compensatory saccade latency and amplitude were moderate (right latency, intraclass correlation coefficient=0.61; left latency, intraclass correlation coefficient=0.69; right amplitude, intraclass correlation coefficient=0.69; left amplitude, intraclass correlation coefficient=0.58). There were no significant effects of age on head impulse paradigm and suppression head impulse paradigm vestibulo-ocular reflex gain values and suppression head impulse paradigmsaccade latency. However, the saccade amplitude became smaller with increasing age, P < .001. The horizontal suppression head impulse paradigm vestibuloocular reflex gain values were significantly lower than the head impulse paradigm for both sides (right, P = .004; left, P = .004). CONCLUSION: There was good test-retest reliability for both measures, and the gain values stabilized with age. However, suppression head impulse paradigm anti-compensatory saccade latency and amplitude had lower test-retest reliability than the gain. The suppression head impulse paradigm vestibulo-ocular reflex gain was lower than the head impulse paradigm and its anti-compensatory saccade amplitude reduced with increasing age. Cite this article as: Sayed SZ, Abdul Wahat NH, Raymond AA, Hussein N, Omar M. Test-retest reliability, effects of age and comparison of horizontal 2 semicircular canals gain values between head impulse and suppression head impulse paradigms. J Int Adv Otol. 2023;19(1):33-40.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Audiology Programme, Centre for Rehabilitation and Special Needs Studies (iCaRehab), Universiti Kebangsaan Malaysia Faculty of Health Sciences, Kuala Lumpur, Malaysia.
- Department of Medicine, Universiti Teknologi MARA Faculty of Medicine, Selangor, Malaysia.
- Department of Rehabilitation Medicine, Hospital Rehabilitasi Cheras, JalanYaacob Latif, Kuala Lumpur, Malaysia.
Zitieren
APA
Sayed, S. Z., Abdul Wahat, N. H., Raymond, A. A., Hussein, N., & Omar, M. (2023). Test-Retest Reliability, Effects of Age and Comparison of Horizontal 2 Semicircular Canals Gain Values between Head Impulse and Suppression Head Impulse Paradigms. The Journal of International Advanced Otology, 19(1), 33-40. https://doi.org/10.5152/iao.2023.21387
Vancouver
Sayed SZ, Abdul Wahat NH, Raymond AA, Hussein N, Omar M. Test-Retest Reliability, Effects of Age and Comparison of Horizontal 2 Semicircular Canals Gain Values between Head Impulse and Suppression Head Impulse Paradigms. The Journal of International Advanced Otology. 2023;19(1):33-40. doi:10.5152/iao.2023.21387
BibTeX
@article{Sayed2023,
author = {Sayed, Sharifah Zainon and Abdul Wahat, Nor Haniza and Raymond, Azman Ali and Hussein, Norhayati and Omar, Marniza},
title = {Test-Retest Reliability, Effects of Age and Comparison of Horizontal 2 Semicircular Canals Gain Values between Head Impulse and Suppression Head Impulse Paradigms},
journal = {The Journal of International Advanced Otology},
year = {2023},
volume = {19},
number = {1},
pages = {33--40},
doi = {10.5152/iao.2023.21387}
}
EUVIMED