EUVIMEDEUVIMED entdecken
Crossref

Performance of C. Diff Quik Chek Complete and RIDASCREEN immunoassays and lack of Ct value concordance between Allplex GI-Bacteria(I) and Xpert Clostridioides difficile assays: a diagnostic accuracy study

Kibum Jeon, Nuri Lee, Hyun Soo Kim, Han-Sung Kim, Wonkeun Song, Jae-Seok Kim

Annals of Clinical Microbiology · 20.03.2026 · 29 (1) · 1-1

DOI: 10.5145/acm.2026.29.1.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Clinical Microbiology, online erschienen am 20.03.2026. Verfasst von Kibum Jeon und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Enzyme immunoassays (EIAs), which detect glutamate dehydrogenase (GDH) and toxin A/B, are widely used to screen for Clostridioides difficile infection (CDI); however, their sensitivity is lower than that of molecular assays. This study aimed to evaluate the performance of two EIAs, C. Diff Quik Chek Complete (QCC) and RIDASCREEN (RIDA), and investigate the cycle threshold (Ct) values from two real-time polymerase chain reaction (PCR) assays (Allplex GI–Bacteria(I) and Xpert C. difficile) in EIA-discordant samples.

Methods

A total of 180 clinical stool samples were tested using QCC, RIDA, and Allplex GI-Bacteria(I) PCR assays. The Xpert C. difficile assay was used to analyze discordant results.

Results

QCC and RIDA showed high sensitivities for GDH detection, 100.0% and 94.4%, respectively. QCC was significantly more sensitive than RIDA for toxin detection (51.4% vs. 28.6%, p = 0.007). In 25 EIA-discordant, Xpert positive samples, the Ct values of the toxin B gene ranged from 31.5 to 44.8 (mean, 38.1) for Allplex PCR and from 23.7 to 36.3 (mean, 30.4) for Xpert PCR. The Ct values of the two PCR assays were not significantly correlated (r = 0.201, p = 0.324).

Conclusion

QCC is a suitable initial immunological test for diagnosing CDI. The lack of correlation in the Ct values between the two real-time PCR assays suggests that assay-specific validation is necessary for cutoff level interpretation.

Zitieren

APA

Jeon, K., Lee, N., Kim, H. S., Kim, H., Song, W., & Kim, J. (2026). Performance of C. Diff Quik Chek Complete and RIDASCREEN immunoassays and lack of Ct value concordance between Allplex GI-Bacteria(I) and Xpert Clostridioides difficile assays: a diagnostic accuracy study. Annals of Clinical Microbiology, 29(1), 1-1. https://doi.org/10.5145/acm.2026.29.1.1

Vancouver

Jeon K, Lee N, Kim HS, Kim H, Song W, Kim J. Performance of C. Diff Quik Chek Complete and RIDASCREEN immunoassays and lack of Ct value concordance between Allplex GI-Bacteria(I) and Xpert Clostridioides difficile assays: a diagnostic accuracy study. Annals of Clinical Microbiology. 2026;29(1):1-1. doi:10.5145/acm.2026.29.1.1

BibTeX
@article{Jeon2026,
  author = {Jeon, Kibum and Lee, Nuri and Kim, Hyun Soo and Kim, Han-Sung and Song, Wonkeun and Kim, Jae-Seok},
  title = {Performance of C. Diff Quik Chek Complete and RIDASCREEN immunoassays and lack of Ct value concordance between Allplex GI-Bacteria(I) and Xpert Clostridioides difficile assays: a diagnostic accuracy study},
  journal = {Annals of Clinical Microbiology},
  year = {2026},
  volume = {29},
  number = {1},
  pages = {1--1},
  doi = {10.5145/acm.2026.29.1.1}
}
Kostenlos starten →