“Small In, Large Out” and “Luster”: vision therapy feedback in adults with normal binocular vision
Medical hypothesis, discovery & innovation in optometry · 31.10.2026 · 7 (3) · 107-115
DOI: 10.51329/mehdioptometry251 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical hypothesis, discovery & innovation in optometry, online erschienen am 31.10.2026. Verfasst von Masoud Khorrami-Nejad und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Feedback is an important component of vision therapy, providing information about visual performance and helping reinforce appropriate binocular responses. However, the frequency of different perceptual responses to commonly used vision therapy feedback techniques has not been well characterized in adults with normal binocular vision. This study aimed to determine the frequency and distribution of responses to the Small In, Large Out (SILO) and Luster vision therapy feedback techniques in a population of adults with normal ocular and binocular vision.
Methods
This cross-sectional observational study included participants with normal ocular examinations and binocular vision. A comprehensive ophthalmic and binocular vision examination was performed, including assessment of refractive error, corrected distance visual acuity (CDVA), stereoacuity, amplitude of accommodation, ocular alignment, and negative and positive fusional vergences (NFV and PFV) at distance and near. SILO feedback responses were assessed using eccentric circles and free-space fusion cards, while Luster feedback was evaluated using variable tranaglyphs (Bernell Corp., USA). SILO responses were classified as SILO, Small Out, Large In (SOLI), other responses, or no response. Luster responses were categorized as Shimmer, Half-half, Blended, Red, or Green.
Results
The study included 195 participants with a mean (standard deviation [SD]) age of 23.7 (4.3) years, 80 (41.0%) females and 115 (59.0%) males. SILO response categories differed significantly from an equal distribution (Chi-Square (3) = 96.47, P < 0.001). SOLI was the most frequently reported response (n = 106, 54.4%), followed by other responses (n = 44, 22.6%), SILO (n = 26, 13.3%), and no response (19, 9.7%). Luster response categories also differed significantly from an equal distribution (Chi-Square (4) = 73.18, P < 0.001). Half-half, Shimmer, Blended, Red, and Green responses were reported by 70 (35.9%), 66 (33.8%), 25 (12.8%), 17 (8.7%), and 17 (8.7%) participants, respectively.
Conclusions
Responses to both SILO and Luster feedback techniques varied considerably in adults with normal ocular and binocular vision, with SOLI predominating in the SILO test and Half-half and Shimmer predominating in the Luster test. These findings characterize the distribution of perceptual responses to these commonly used vision therapy techniques and provide descriptive reference data for interpreting feedback responses in similar adult populations. Future studies should investigate the reproducibility of these response patterns across diverse populations and determine their clinical relevance to vision therapy outcomes.
Zitieren
APA
Khorrami-Nejad, M., Mohsin, M. K., Yousefi, R., Jaber, H. N., & Jafarzadehpur, E. (2026). “Small In, Large Out” and “Luster”: vision therapy feedback in adults with normal binocular vision. Medical hypothesis, discovery & innovation in optometry, 7(3), 107-115. https://doi.org/10.51329/mehdioptometry251
Vancouver
Khorrami-Nejad M, Mohsin MK, Yousefi R, Jaber HN, Jafarzadehpur E. “Small In, Large Out” and “Luster”: vision therapy feedback in adults with normal binocular vision. Medical hypothesis, discovery & innovation in optometry. 2026;7(3):107-115. doi:10.51329/mehdioptometry251
BibTeX
@article{KhorramiNejad2026,
author = {Khorrami-Nejad, Masoud and Mohsin, Mohammed Khalaf and Yousefi, Reza and Jaber, Hadeel Nashee and Jafarzadehpur, Ebrahim},
title = {“Small In, Large Out” and “Luster”: vision therapy feedback in adults with normal binocular vision},
journal = {Medical hypothesis, discovery & innovation in optometry},
year = {2026},
volume = {7},
number = {3},
pages = {107--115},
doi = {10.51329/mehdioptometry251}
}
EUVIMED