EUVIMEDEUVIMED entdecken
Querschnittstudie

Use of automatic refractometer infrared images to screen pigment dispersion syndrome: a cross-sectional observational study from a preliminary hypothesis

Paolo Brusini, Veronica Papa

Medical Hypothesis, Discovery & Innovation in Optometry · 2020

DOI: 10.51329/mehdioptometry104 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Medical Hypothesis, Discovery & Innovation in Optometry, 2020. Verfasst von Paolo Brusini und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study was performed to evaluate the use of anterior segment images, obtained with an automatic refractometer, to identify early defects of the iris pigment epithelium in patients with pigment dispersion syndrome (PDS) or pigmentary glaucoma (PG) without observable alterations at the slit lamp.

Methods

In this cross-sectional observational study, carried out from January 2018 to December 2019, in Policlinico Citta di Udine Health Center, Udine, Italy, we observed anterior segment infrared images of 1700 subjects who were undergoing routine ophthalmological examination using an automatic refractometer. We selected infrared images of subjects who fulfilled the inclusion and exclusion criteria and looked for a focal defect in the iris pigment epithelium.

Results

Twenty patients with focal iris pigment epithelial defect were identified and none of them showed evident signs of PDS. After the necessary explanations, they agreed to have further examinations to verify the possibility of PDS. An in-depth evaluation of ocular structures, including gonioscopy, demonstrated the presence of PDS in all subjects with iris defects.

Conclusions

The use of infrared images obtained by an automatic refractometer could provide early and easy identification of PDS in crowded ophthalmology clinics or mass screening programs; yet, more well-designed studies are necessary to confirm these preliminary findings and prove this proposed screening tool.

Zitieren

APA

Brusini, P., & Papa, V. (2020). Use of automatic refractometer infrared images to screen pigment dispersion syndrome: a cross-sectional observational study from a preliminary hypothesis. Medical Hypothesis, Discovery & Innovation in Optometry. https://doi.org/10.51329/mehdioptometry104

Vancouver

Brusini P, Papa V. Use of automatic refractometer infrared images to screen pigment dispersion syndrome: a cross-sectional observational study from a preliminary hypothesis. Medical Hypothesis, Discovery & Innovation in Optometry. 2020. doi:10.51329/mehdioptometry104

BibTeX
@article{Brusini2020,
  author = {Brusini, Paolo and Papa, Veronica},
  title = {Use of automatic refractometer infrared images to screen pigment dispersion syndrome: a cross-sectional observational study from a preliminary hypothesis},
  journal = {Medical Hypothesis, Discovery & Innovation in Optometry},
  year = {2020},
  doi = {10.51329/mehdioptometry104}
}
Kostenlos starten →