Monocanalicular Versus Bicanalicular Stent in Transcanalicular Diode Laser Dacryocystorhinostomy
Pakistan Armed Forces Medical Journal · 30.06.2026 · 76 (3) · 357-361
DOI: 10.51253/pafmj.v76i3.12288 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pakistan Armed Forces Medical Journal, online erschienen am 30.06.2026. Verfasst von Quratulain Paracha und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To assess the success rate of monocanalicular versus bicanalicular intubation to maintain the patency of ostium following TDL-DCR. Study design: Quasi-Experimental Study. Place and Duration of Study: Ophthalmology Department PNS Shifa Hospital, Karachi, Pakistan from Mar to Aug 2023. Methodology: A total of 246 patients with acquired nasolacrimal duct obstruction were operated for TDL-DCR using an Intermedic Diode laser (810nm) to create the bony ostium. They were randomly divided into Groups I and II for monocanalicular and bicanalicular stents respectively. Sac syringing and probing were done at follow-up visits on day 1, week 1, months 1, 3, and 6.
Results
There were 129(52.84%) females and 116(47.15%) males. Their mean age was 46.30±13.44 years. The right side was affected in 115(46.74%) and left in 105(42.68%) while bilateral blockade was present in 26 (10.6%) cases. At 6 months postoperatively 90(73.2%) in Group I and 94(76.4%) in Group II (p:0.68) patients had patent ostium and no epiphora was present in 75 (61%) and 80 (65%) patients (p:0.71) respectively. At 3 months postoperative 47(38.2%) patients in Group I and 91(74%) in Group II had the silicone stent removed by the surgeon. Spontaneous stent prolapse was noted in 68(55.3%) patients in Group I and 22(17.9%) in Group II. (p:0.27)
Conclusion
Both monocanalicular and bicanalicular intubation are effective in keeping the ostium patent after TDL-DCR. We recommend large-scale studies to establish any preference for mono or bicanalicular intubation.
Zitieren
APA
Paracha, Q., Yasin, U., Saeed, M. K., Farooq, O., & Urooj, S. (2026). Monocanalicular Versus Bicanalicular Stent in Transcanalicular Diode Laser Dacryocystorhinostomy. Pakistan Armed Forces Medical Journal, 76(3), 357-361. https://doi.org/10.51253/pafmj.v76i3.12288
Vancouver
Paracha Q, Yasin U, Saeed MK, Farooq O, Urooj S. Monocanalicular Versus Bicanalicular Stent in Transcanalicular Diode Laser Dacryocystorhinostomy. Pakistan Armed Forces Medical Journal. 2026;76(3):357-361. doi:10.51253/pafmj.v76i3.12288
BibTeX
@article{Paracha2026,
author = {Paracha, Quratulain and Yasin, Ubaidullah and Saeed, Muhammad Kamran and Farooq, Omer and Urooj, Summaiya},
title = {Monocanalicular Versus Bicanalicular Stent in Transcanalicular Diode Laser Dacryocystorhinostomy},
journal = {Pakistan Armed Forces Medical Journal},
year = {2026},
volume = {76},
number = {3},
pages = {357--361},
doi = {10.51253/pafmj.v76i3.12288}
}
EUVIMED