EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Test-retest reliability of postural sway on foam and natural rubber pads in healthy adults

Chuanpis Boonkerd, Yatiga Archasawat, Wachiraporn Sertkhamsorn, Panida Saensanoh, Teerapat Laddawong, Thanawat Kitsuksan

Physiotherapy Quarterly · 21.06.2024 · 32 (2) · 32-38

DOI: 10.5114/pq/157145 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiotherapy Quarterly, online erschienen am 21.06.2024. Verfasst von Chuanpis Boonkerd und 5 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Postural control is essential for humans to maintain balance under both static and dynamic conditions. A variety of unstable support surfaces are used to evaluate postural control. Balance foam pads are relatively expensive, whereas natural rubber pads use a natural material with equivalent viscoelastic properties that are inexpensive and widely available. No postural sway and reliable data existed to support the practice of using a natural rubber pad. The purposes of the study were to determine the test-retest reliability of postural sway by using a natural rubber pad and to compare postural sway in healthy adults while using a foam pad, a natural rubber pad and a firm surface.

Methods

Nineteen healthy participants were measured for centre of pressure (COP) velocity and displacement during a quiet stance, with their eyes closed, on a balance foam pad (blue foam – Airex®), a natural rubber pad and a firm surface on a force platform. Two repeated sessions were conducted three days apart. Intraclass correlation coefficients were used to determine the test-retest reliability. A one-way repeated measures ANOVA was used to compare the three surface conditions.

Results

The natural rubber pad demonstrated moderate to good reliability for COP velocity and COP displacement. Also, there were no significant differences in anteroposterior (AP) and mediolateral (ML) COP velocity and displacement between the balance foam pad and the natural rubber pad.

Conclusions

Our findings indicate that a natural rubber pad could be employed as a low-cost alternative to the balance foam pad for evaluating the balance of healthy adults.

Zitieren

APA

Boonkerd, C., Archasawat, Y., Sertkhamsorn, W., Saensanoh, P., Laddawong, T., & Kitsuksan, T. (2024). Test-retest reliability of postural sway on foam and natural rubber pads in healthy adults. Physiotherapy Quarterly, 32(2), 32-38. https://doi.org/10.5114/pq/157145

Vancouver

Boonkerd C, Archasawat Y, Sertkhamsorn W, Saensanoh P, Laddawong T, Kitsuksan T. Test-retest reliability of postural sway on foam and natural rubber pads in healthy adults. Physiotherapy Quarterly. 2024;32(2):32-38. doi:10.5114/pq/157145

BibTeX
@article{Boonkerd2024,
  author = {Boonkerd, Chuanpis and Archasawat, Yatiga and Sertkhamsorn, Wachiraporn and Saensanoh, Panida and Laddawong, Teerapat and Kitsuksan, Thanawat},
  title = {Test-retest reliability of postural sway on foam and natural rubber pads in healthy adults},
  journal = {Physiotherapy Quarterly},
  year = {2024},
  volume = {32},
  number = {2},
  pages = {32--38},
  doi = {10.5114/pq/157145}
}
Kostenlos starten →