Reliability of anterior cruciate ligament (ACL) graft signal intensity measurement on MRI: a novel method with intra- and interrater analysis over a 1-week interval

Wojciech Szewczyk, Michał Marek, Florian Forelli, Maciej Biały

Polish Journal of Radiology · 22.06.2026 · 91 (1) · 299-305

DOI: 10.5114/pjr/218236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polish Journal of Radiology, online erschienen am 22.06.2026. Verfasst von Wojciech Szewczyk und 3 weiteren Autor:innen. Beteiligte Einrichtung: Helimed Diagnostic Imaging, Żory, Poland. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To determine the intra- and interrater reliability of the anterior cruciate ligament (ACL) graft signal-to-noise quotient (SNQ) assessed on magnetic resonance imaging (MRI) using a standardized coronal-oblique plane and region-of-interest (ROI) measurement protocol. Material and methods Twelve adults following ACL reconstruction underwent MRI graft assessment. Five ROIs were placed along the intra-articular portion of the ACL graft. Posterior cruciate ligament (PCL) and background ROIs were used for SNQ normalization (SNQ = [ACL signal − PCL signal]/background signal). Two radiologists independently performed two blinded measurement sessions, 1 week apart. Reliability included intraclass correlation coefficients (ICCs), 95% confidence intervals (CIs), standard error of measurement (SEM), and smallest detectable difference (SDD).

Results

Intrarater ICCs for individual ROIs ranged from 0.67 to 0.90, with the highest reliability at R2 (ICC = 0.90; 95% CI: 0.70-0.97) and the lowest at R5 (ICC = 0.67; 95% CI: 0.20-0.89). Corresponding SEM values ranged from 0.31 to 1.01 and SDD from 0.87 to 2.79. Interrater ICCs ranged from 0.52 to 0.83, again highest at R2 (ICC = 0.83; 95% CI: 0.65-0.92) and lowest at R5 (ICC = 0.52; 95% CI: 0.15-0.76). Interrater SEM values ranged from 0.51 to 1.23 and SDD from 1.43 to 3.43. Averaging SNQ across all five ROIs improved reliability, yielding excellent intrarater agreement (ICC = 0.90; 95% CI: 0.67-0.97; SEM = 0.28; SDD = 0.76) and good interrater agreement (ICC = 0.85; 95% CI: 0.67-0.93; SEM = 0.34; SDD = 0.96).

Conclusions

The proposed MRI-based SNQ protocol demonstrates excellent intrarater and good interrater reliability over a 1-week interval. ROI averaging meaningfully enhances reproducibility and provides actionable SDD thresholds for detecting ACL graft signal change.

Schlagwörter

Stichwörter der Autor:innen

anterior cruciate ligament reconstructiongraft signal intensitymagnetic resonance imagingmeasurement reliabilitysignal-to-noise quotient

Autor:innen und Institutionen

  • Helimed Diagnostic Imaging, Żory, Poland.
  • Haute-Ecole Arc Santé, HES-SO University of Applied Sciences and Arts Western Switzerland, Delémont, Switzerland.
  • Orthopaedic Surgery Department, OrthoLab, Clinic of Domont, Domont, France.
  • Institute of Physiotherapy and Health Sciences, Academy of Physical Education, Katowice, Poland.

Zitieren

APA

Szewczyk, W., Marek, M., Forelli, F., & Biały, M. (2026). Reliability of anterior cruciate ligament (ACL) graft signal intensity measurement on MRI: a novel method with intra- and interrater analysis over a 1-week interval. Polish Journal of Radiology, 91(1), 299-305. https://doi.org/10.5114/pjr/218236

Vancouver

Szewczyk W, Marek M, Forelli F, Biały M. Reliability of anterior cruciate ligament (ACL) graft signal intensity measurement on MRI: a novel method with intra- and interrater analysis over a 1-week interval. Polish Journal of Radiology. 2026;91(1):299-305. doi:10.5114/pjr/218236

BibTeX
@article{Szewczyk2026,
  author = {Szewczyk, Wojciech and Marek, Michał and Forelli, Florian and Biały, Maciej},
  title = {Reliability of anterior cruciate ligament (ACL) graft signal intensity measurement on MRI: a novel method with intra- and interrater analysis over a 1-week interval},
  journal = {Polish Journal of Radiology},
  year = {2026},
  volume = {91},
  number = {1},
  pages = {299--305},
  doi = {10.5114/pjr/218236}
}
Kostenlos starten →