Comparative accuracy of two CBCT scanners with different fields of view for measurement of radicular dentin thickness of maxillary first molars
Journal of Stomatology · 2026 · 79 (2) · 115-125
DOI: 10.5114/jos.2026.163649 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Stomatology, 2026. Verfasst von Foozie Zahedi und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Radiography is the most commonly recommended modality for measurement of residual dentin thickness.Cone beam computed tomography (CBCT) is an accurate method for most linear measure ments, but its measurement accuracy can be influenced by field of view (FOV) and voxel size.
Objectives
This study compared the accuracy of two CBCT scanners with different FOVs for measurement of radicular dentin thickness of maxillary first molars. Material and methods:In this in vitro study, 50 extracted maxillary first molars were decoronated, embedded in paraffin blocks, and scanned using Carestream CBCT with 4 × 4 cm and 5 × 8 cm FOVs (75 μm) voxel size as well as Cranex 3D with 4 × 6 cm (136 μm) and 6 × 8 cm FOVs (200 μm).Two observers measured radicular dentin thickness of mesiobuccal and palatal roots at furcation, and 2 mm and 4 mm below it, using OnDemand software.Horizontal sections were made at the same levels, and actual dentin thickness was measured with a digi tal caliper as the gold standard.Paired ttests were used for comparison (α = 0.05). Results:The interobserver agreement was acceptable (> 0.780).Carestream with large FOV and Cranex with small FOV showed acceptable accuracy, with a difference of 0.03 mm and 0.08 mm between the two FOVs, re spectively (p 0.05).
Conclusions
Cranex was more accurate than Carestream in small FOV.Small FOV provided a higher measu rement accuracy than large FOV.Although it was clinically negligible, small FOV should be preferred for endo dontics cases diagnosed with CBCT to minimize radiation dose while maintaining accuracy.
Zitieren
APA
Zahedi, F., Najafi, E., Shokri, A., Foroozandeh, M., Heydari, S., & Tapak, L. (2026). Comparative accuracy of two CBCT scanners with different fields of view for measurement of radicular dentin thickness of maxillary first molars. Journal of Stomatology, 79(2), 115-125. https://doi.org/10.5114/jos.2026.163649
Vancouver
Zahedi F, Najafi E, Shokri A, Foroozandeh M, Heydari S, Tapak L. Comparative accuracy of two CBCT scanners with different fields of view for measurement of radicular dentin thickness of maxillary first molars. Journal of Stomatology. 2026;79(2):115-125. doi:10.5114/jos.2026.163649
BibTeX
@article{Zahedi2026,
author = {Zahedi, Foozie and Najafi, Elahe and Shokri, Abbas and Foroozandeh, Maryam and Heydari, Shamsodin and Tapak, Leili},
title = {Comparative accuracy of two CBCT scanners with different fields of view for measurement of radicular dentin thickness of maxillary first molars},
journal = {Journal of Stomatology},
year = {2026},
volume = {79},
number = {2},
pages = {115--125},
doi = {10.5114/jos.2026.163649}
}
EUVIMED