EUVIMEDEUVIMED entdecken
Open Access

T wave positivity in lead aVR is associated with mortality after transcatheter aortic valve implantation

Yurdaer Dönmez, Örsan Deniz Urgun, İbrahim Halil Kurt

Archives of Medical Science – Atherosclerotic Diseases · 12.04.2019 · 4 (1) · 55-62

DOI: 10.5114/amsad.2019.84449 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Medical Science – Atherosclerotic Diseases, online erschienen am 12.04.2019. Verfasst von Yurdaer Dönmez und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University of Health Sciences - Adana Health Practices and Research Centre, Adana, Turkey. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Transcatheter aortic valve implantation (TAVI) is an alternative to surgical aortic valve replacement (SAVR) in patients with increased comorbidity. Lead aVR in surface ECG has valuable information about prediction of mortality in many cardiovascular diseases. Our aim was to determine the relationship between ischemic changes in lead aVR and mortality in TAVI patients. Material and methods We retrospectively examined 86 patients with TAVI. The ST segment deviation in lead aVR (STaVR) and T wave polarity (TPaVR) on surface ECG were measured. The absolute values of TPaVR and STaVR were calculated. A ratio (TP/STaVR or vice versa) was obtained from the division of the larger absolute value by the smaller one.

Results

The patients were divided into two groups as living and deceased. The living group had 68 patients, and the deceased group had 18 patients. The number of positive TPaVR patients after TAVI, TPaVR after TAVI, and TP/STaVR ratio after TAVI were significantly higher in the deceased group. The deceased group had a significantly shorter aortic annulus-LMCA distance. Presence of positive TPaVR (OR = 8.765, 95% CI: 1.088–70.618, p = 0.041), aortic annulus-LMCA distance (for each 1 mm increase, OR = 0.306, 95% CI: 0.158–0.595, p < 0.001) and TP/STaVR ratio (for each 0.1 increase, OR = 1.966, 95% CI: 1.276–3.024, p = 0.002) were determined as independent predictors for mortality.

Conclusions

Ischemic changes in lead aVR may provide valuable information about mortality after TAVI.

Schlagwörter

Stichwörter der Autor:innen

electrocardiogramlead aVRmortalitytranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Department of Cardiology, University of Health Sciences - Adana Health Practices and Research Centre, Adana, Turkey.

Zitieren

APA

Dönmez, Y., Urgun, Ö. D., & Kurt, İ. H. (2019). T wave positivity in lead aVR is associated with mortality after transcatheter aortic valve implantation. Archives of Medical Science – Atherosclerotic Diseases, 4(1), 55-62. https://doi.org/10.5114/amsad.2019.84449

Vancouver

Dönmez Y, Urgun ÖD, Kurt İH. T wave positivity in lead aVR is associated with mortality after transcatheter aortic valve implantation. Archives of Medical Science – Atherosclerotic Diseases. 2019;4(1):55-62. doi:10.5114/amsad.2019.84449

BibTeX
@article{Dnmez2019,
  author = {Dönmez, Yurdaer and Urgun, Örsan Deniz and Kurt, İbrahim Halil},
  title = {T wave positivity in lead aVR is associated with mortality after transcatheter aortic valve implantation},
  journal = {Archives of Medical Science – Atherosclerotic Diseases},
  year = {2019},
  volume = {4},
  number = {1},
  pages = {55--62},
  doi = {10.5114/amsad.2019.84449}
}
Kostenlos starten →