Fachartikel in der Zeitschrift Advances in Interventional Cardiology, 2026. Verfasst von Paweł Latacz und 1 weiteren Autor:innen. Beteiligte Einrichtung: Chair of Radiology, Jagiellonian University Medical College, Krakow, Poland. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

initial critical stenosis. B – Follow-up angiography at 4 weeks shows approximately 80% thrombosis of the aneurysm, with persistent inflow into the space around the stent. Bending and narrowing of the stent at the site of the initial critical stenosis are visible (confirmed by IVUS). C – Balloon angioplasty at the site of the most critical stenoses (repeated several times). D – Final angiographic result after balloon angioplasty and RoadSaver stent implantation; IVUS confirmed good apposition of the stents to the arterial wall. E – Residual non-oc-cluded portion of the aneurysm. F – 4-month follow-up angiography after balloon angioplasty and RoadSaver stent implantation shows full expansion of the stent but persistent contrast inflow into the space around the stent. The non-occluded part of the aneurysm measures up to 44 × 23 mm; IVUS shows good stent apposition in the distal segment of the stent. G – Positioning of a covered stent – previously implanted stents provided a framework that allowed for successful navigation and positioning of the final stent. H – Final result after implantation of the Viabahn covered stent (stent between the arrows). There is no inflow into the aneurysmal sac, and flow in the internal carotid artery and intracranial arteries is normal

Autor:innen und Institutionen

  • Chair of Radiology, Jagiellonian University Medical College, Krakow, Poland.
  • Department of Vascular Surgery and Angiology, Brothers of Mercy St. John Grande's Hospital, Krakow, Poland.
  • Department of Anatomy, University of Opole, Poland.

Zitieren

APA

Latacz, P., & Simka, M. (2026). Multistaged endovascular management of a complex extracranial internal carotid artery aneurysm using a new-generation flow diverter CARESTO® heal Stent and 3D printing simulation. Advances in Interventional Cardiology, 22(2), 286-290. https://doi.org/10.5114/aic.2026.161973

Vancouver

Latacz P, Simka M. Multistaged endovascular management of a complex extracranial internal carotid artery aneurysm using a new-generation flow diverter CARESTO® heal Stent and 3D printing simulation. Advances in Interventional Cardiology. 2026;22(2):286-290. doi:10.5114/aic.2026.161973

BibTeX
@article{Latacz2026,
  author = {Latacz, Paweł and Simka, Marian},
  title = {Multistaged endovascular management of a complex extracranial internal carotid artery aneurysm using a new-generation flow diverter CARESTO® heal Stent and 3D printing simulation},
  journal = {Advances in Interventional Cardiology},
  year = {2026},
  volume = {22},
  number = {2},
  pages = {286--290},
  doi = {10.5114/aic.2026.161973}
}
Kostenlos starten →