Comments on Oral Sulfate Solution Is as Effective as Polyethylene Glycol with Ascorbic Acid in a Split Method for Bowel Preparation in Patients with Inactive Ulcerative Colitis: A Randomized, Multicenter, and Single-Blind Clinical Trial
Gut and Liver · 2024
DOI: 10.5009/gnl230355 ↗Kurz gefasst
Leserbrief in der Zeitschrift Gut and Liver, 2024. Verfasst von Ji Eun Kim. Beteiligte Einrichtung: Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Colitis, Ulcerative, Polyethylene Glycols. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background/Aims: Endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is essential in diagnosing solid pancreatic lesions (SPLs), but without rapid on-site evaluation (ROSE), a repeat EUS-FNA/B is crucial for clarifying an inconclusive diagnosis. We aimed to evaluate factors associated with improved diagnostic performance of repeat EUS-FNA/B for initially inconclusive SPL diagnoses without ROSE.
Methods
Of 5,894 patients subjected to EUS-FNA/B, 237 (4.0%) with an initially inconclusive diagnosis of SPLs were retrospectively enrolled from five tertiary medical centers between January 2016 and June 2021. Diagnostic performance and procedural factors of EUS-FNA/B were analyzed.
Results
The diagnostic accuracies of first and repeat EUS-FNA/B were 96.2% and 67.6%, respectively. Of 237 patients with an inconclusive diagnosis from initial EUS-FNA/B, 150 were pathologically diagnosed after repeat EUS-FNA/B. In multivariate analysis of repeat EUS-FNA/B, tumor location (body/tail vs head: odds ratio [OR], 3.74; 95% confidence interval [CI], 1.48 to 9.46), number of needle passes (≥4 vs ≤3: OR, 4.80; 95% CI, 1.44 to 15.99), needle type (FNB vs FNA: OR, 3.26; 95% CI, 1.44 to 7.36), needle size (22 gauge vs 19/20 gauge: OR, 2.35; 95% CI, 1.19 to 4.62), and suction method (suction vs others: OR, 5.19; 95% CI, 1.30 to 20.75) were associated with a significantly improved diagnostic performance.
Conclusions
Repeat EUS-FNA/B is essential for patients with an inconclusive EUS-FNA/B without ROSE. To improve the diagnostic performance of repeated EUS-FNA/B, it is recommended that 22-gauge FNB needles, ≥4 needle passes, and suction methods are used.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
ORCID-Profile: Ji Eun Kim
Zitieren
APA
Kim, J. E. (2024). Comments on Oral Sulfate Solution Is as Effective as Polyethylene Glycol with Ascorbic Acid in a Split Method for Bowel Preparation in Patients with Inactive Ulcerative Colitis: A Randomized, Multicenter, and Single-Blind Clinical Trial. Gut and Liver. https://doi.org/10.5009/gnl230355
Vancouver
Kim JE. Comments on Oral Sulfate Solution Is as Effective as Polyethylene Glycol with Ascorbic Acid in a Split Method for Bowel Preparation in Patients with Inactive Ulcerative Colitis: A Randomized, Multicenter, and Single-Blind Clinical Trial. Gut and Liver. 2024. doi:10.5009/gnl230355
BibTeX
@article{Kim2024,
author = {Kim, Ji Eun},
title = {Comments on Oral Sulfate Solution Is as Effective as Polyethylene Glycol with Ascorbic Acid in a Split Method for Bowel Preparation in Patients with Inactive Ulcerative Colitis: A Randomized, Multicenter, and Single-Blind Clinical Trial},
journal = {Gut and Liver},
year = {2024},
doi = {10.5009/gnl230355}
}
EUVIMED