EUVIMEDEUVIMED entdecken
Crossref

Intra-articular Glenoid Fracture Managed by Arthroscopic Fixation and Open Reduction and Internal Fixation Techniques: An Analytical Study

Sivakumar Raju, Prahalad Kumar Singhi, Vinoth Thangamani, Chidambaram Muthu, MuthuKishore Marichamy, Gopi Kumarasamy

Journal of Orthopedics and Joint Surgery · 2024

DOI: 10.5005/jojs-10079-1129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopedics and Joint Surgery, 2024. Verfasst von Sivakumar Raju und 5 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Intra-articular glenoid fractures are rare injuries. Due to complex anatomy and neurovascular structures in vicinity, operative treatment is relatively uncommon. With the advent of three-dimensional (3D) computed tomography (CT), appropriate analysis of fracture pattern and management protocols can be developed. Operative treatment has evolved from extensive open reduction to arthroscopic surgery. Here, we analyzed the intra-articular glenoid fractures, which were managed by conservative, open, or arthroscopic fixation (ARIF) to derive a treatment algorithm. Materials and methods: All the shoulder fractures which presented to our hospital from January 2018 to December 2020 were screened for intra-articular glenoid fractures. An institutional treatment algorithm was followed for 10 such fractures, where four underwent ARIF, four by open reduction, and two were conserved. These patients were followed up, and functional evaluation with Constant–Murley and the University of California, Los Angeles (UCLA) scoring system were done. Results and discussion: The mean constant score at 1 and 2 years follow-up were 63.2 ± 9.3 and 78 ± 9.7, respectively. The mean UCLA score at 1 and 2 years follow-up were 23.7 ± 4.4 and 28.3 ± 3.7, respectively. At the end of 2 years’ follow-up, all these patients had good to excellent outcome. One patient had shoulder stiffness; clavicle elastic nail was removed in two cases as it caused irritation at entry site and no other major complications.

Conclusion

Intra-articular glenoid fractures are uncommon injuries but can end up in severe morbidity if neglected or not aptly treated. Anatomical restoration of the articular surface is the goal in management of intra-articular glenoid fractures. Undisplaced fractures or articular step-off

Zitieren

APA

Raju, S., Singhi, P. K., Thangamani, V., Muthu, C., Marichamy, M., & Kumarasamy, G. (2024). Intra-articular Glenoid Fracture Managed by Arthroscopic Fixation and Open Reduction and Internal Fixation Techniques: An Analytical Study. Journal of Orthopedics and Joint Surgery. https://doi.org/10.5005/jojs-10079-1129

Vancouver

Raju S, Singhi PK, Thangamani V, Muthu C, Marichamy M, Kumarasamy G. Intra-articular Glenoid Fracture Managed by Arthroscopic Fixation and Open Reduction and Internal Fixation Techniques: An Analytical Study. Journal of Orthopedics and Joint Surgery. 2024. doi:10.5005/jojs-10079-1129

BibTeX
@article{Raju2024,
  author = {Raju, Sivakumar and Singhi, Prahalad Kumar and Thangamani, Vinoth and Muthu, Chidambaram and Marichamy, MuthuKishore and Kumarasamy, Gopi},
  title = {Intra-articular Glenoid Fracture Managed by Arthroscopic Fixation and Open Reduction and Internal Fixation Techniques: An Analytical Study},
  journal = {Journal of Orthopedics and Joint Surgery},
  year = {2024},
  doi = {10.5005/jojs-10079-1129}
}
Kostenlos starten →