EUVIMEDEUVIMED entdecken
Crossref

Supra-aortic trunk anatomy and the limits of off-the-shelf endografts: a narrative review

Luís D. Fernandes, Marta M. Machado, Francisco Basílio, Patrícia Carvalho, Beatriz Guimarães, Ana Margarida Rocha, Diogo Silveira, Alexandra Canedo

Angiologia e Cirurgia Vascular · 2026 · 22 (2)

DOI: 10.48750/acv.675 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Angiologia e Cirurgia Vascular, 2026. Verfasst von Luís D. Fernandes und 7 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To review and synthesize current evidence on the anatomical considerations of supra- aortic trunks (SATs) and their impact on the feasibility and design of off- the- shelf (OTS) and custom- made endografts in endovascular aortic arch repair. METHODS: A narrative review was conducted using PubMed and Scopus databases, focusing on studies evaluating SAT morphology, spatial orientation, and device applicability. Studies addressing clock- face orientation, vessel diameters, inter- branch distances, and anatomical suitability for branched or fenestrated devices were included. RESULTS: Anatomical studies revealed significant variation in SAT configuration, particularly inter- vessel spacing and clock- face orientation. While some consistency in takeoff angles exists, only a subset of patients met the criteria for current OTS devices. Proposed configurations in planning studies—particularly those involving a large left common carotid artery scallop and left subclavian artery fenestration or inner branches—may cover up to 85–97% of cases. Still, challenges remain due to arch angulation, large ascending diameters, and rotational misalignment in tortuous anatomy. Custom- made devices provide high anatomical conformity but are impractical in urgent settings due to production delays. CONCLUSIONS: Anatomical variability remains a key limitation in the broader application of OTS devices for total endovascular aortic arch repair. However, strategic graft design may allow a limited set of configurations to accommodate most patient anatomies. Standardized preoperative measurements and continued refinement of device designs are essential to improving procedural success and expanding clinical applicability.

Schlagwörter

BEVARFEVAREndovascular complex repairRenal stent occlusion

Zitieren

APA

Fernandes, L. D., Machado, M. M., Basílio, F., Carvalho, P., Guimarães, B., Rocha, A. M., Silveira, D., & Canedo, A. (2026). Supra-aortic trunk anatomy and the limits of off-the-shelf endografts: a narrative review. Angiologia e Cirurgia Vascular, 22(2). https://doi.org/10.48750/acv.675

Vancouver

Fernandes LD, Machado MM, Basílio F, Carvalho P, Guimarães B, Rocha AM, et al. Supra-aortic trunk anatomy and the limits of off-the-shelf endografts: a narrative review. Angiologia e Cirurgia Vascular. 2026;22(2). doi:10.48750/acv.675

BibTeX
@article{Fernandes2026,
  author = {Fernandes, Luís D. and Machado, Marta M. and Basílio, Francisco and Carvalho, Patrícia and Guimarães, Beatriz and Rocha, Ana Margarida and Silveira, Diogo and Canedo, Alexandra},
  title = {Supra-aortic trunk anatomy and the limits of off-the-shelf endografts: a narrative review},
  journal = {Angiologia e Cirurgia Vascular},
  year = {2026},
  volume = {22},
  number = {2},
  doi = {10.48750/acv.675}
}
Kostenlos starten →