EUVIMEDEUVIMED entdecken
Crossref

Tailoring Extended Depth-of-Focus Intraocular Lens Design with Pupil Diameter and Spherical Aberration Profile

Bruno Barbosa Ribeiro, Heitor Marques, João, Abreu, Ana Carolina, Monteiro, Sílvia, Menéres, Pedro, Pinto, Maria do Céu

Oftalmologia · 18.10.2024

DOI: 10.48560/rspo.38167 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oftalmologia, erschienen am 18.10.2024. Verfasst von Bruno Barbosa Ribeiro und 10 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Several intraocular lens (IOL) designs have been designed for the correction of presbyopia. The purpose of this study is to evaluate the visual performance of two IOL models and their variation according to spherical aberration (SA) and pupil diameter (PD). METHODS: Prospective analysis of all patients implanted with AcrySoft Vivity (“VIVITY”) or Precizon Presbyopic NVA (“PRESBY”) at the Refractive Surgery Unit of a tertiary hospital between January 2021 and December 2023. Patients with incomplete follow-up, amblyopia, and posterior capsule opacification were excluded. Defocus curve testing was performed at 0.5 diopters (D) intervals from +1.0 D to -3.0 D at the same examination room. PD, chord μ, and corneal wavefront profile was registered using a Scheimpflug system (Pentacam, Oculus). RESULTS: We included 99 eyes of 54 patients - 50 eyes from the VIVITY group and 49 eyes from the PRESBY group. Baseline evaluation showed no significant differences. The VIVITY group showed better intermediate vision (logMAR 0.07 ± 0.06 vs 0.21 ± 0.25, p

Schlagwörter

extended depth of focus intraocular lenspresbyopiaspherical aberrationpupil sizeintermediate visionnear visiondefocus curvevisual performanceintraocular lens designScheimpflug imaging

Zitieren

APA

Ribeiro, B. B., Marques, H., João, Abreu, Carolina, A., Monteiro, Sílvia, Menéres, Pedro, Pinto, & Céu, M. D. (2024). Tailoring Extended Depth-of-Focus Intraocular Lens Design with Pupil Diameter and Spherical Aberration Profile. Oftalmologia. https://doi.org/10.48560/rspo.38167

Vancouver

Ribeiro BB, Marques H, João, Abreu, Carolina A, Monteiro, et al. Tailoring Extended Depth-of-Focus Intraocular Lens Design with Pupil Diameter and Spherical Aberration Profile. Oftalmologia. 2024. doi:10.48560/rspo.38167

BibTeX
@article{Ribeiro2024,
  author = {Ribeiro, Bruno Barbosa and Marques, Heitor and João and Abreu and Carolina, Ana and Monteiro and Sílvia and Menéres and Pedro and Pinto and Céu, Maria do},
  title = {Tailoring Extended Depth-of-Focus Intraocular Lens Design with Pupil Diameter and Spherical Aberration Profile},
  journal = {Oftalmologia},
  year = {2024},
  doi = {10.48560/rspo.38167}
}
Kostenlos starten →