Comparative Evaluation of Retention of Different Luting Cements for Im plant-Supported Crowns: An In Vitro Study
Academia Journal of Medicine · 13.01.2026 · 9 (1) · 26-29
DOI: 10.48165/ajm.2026.9.01.7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academia Journal of Medicine, online erschienen am 13.01.2026. Verfasst von Mohammed Subhan I und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Background
Retention of implant-supported crowns is a critical factor influencing the long-term success of implant prostheses. The choice of luting cement plays an important role in determining the retentive strength, retrievability, and clinical performance of cement retained implant restorations.
Aim
To comparatively evaluate the retention of implant-supported crowns cemented with zinc phosphate cement, resin cement, and resin-modified glass ionomer cement using a universal testing machine in an in vitro setting. Materials and Methods: Thirty implant–abutment–crown assemblies were fabricated and divided into three groups (n = 10) based on the luting cement used: Group I—zinc phosphate cement, Group II—resin cement, and Group III—resin-modified glass ionomer cement. Standardized full-coverage metal crowns were cemented onto prefabricated titanium abutments following manufacturer instructions. All specimens were stored in distilled water at 37°C for 24 hours. Retention was evaluated by applying a tensile load along the long axis of the implant using a universal testing machine at a crosshead speed of 1 mm/min until crown dislodgement occurred. The maximum pull-out force required was recorded in Newtons and statistically analyzed.
Results
The highest mean retentive strength was observed in the resin cement group, followed by resin-modified glass ionomer cement, while zinc phosphate cement demonstrated the lowest retention. Statistical analysis revealed a significant difference in pull-out force values among the three groups (p < 0.05).
Conclusion
Within the limitations of this in vitro study, resin cement provided superior retention for implant-supported crowns compared to resin-modified glass ionomer cement and zinc phosphate cement. Selection of luting cement should consider the balance between retention requirements and the need for retrievability in implant prosthodontics.
Zitieren
APA
I, M. S., Erraguntala, H., Chaudhary, V., Sojitra, M., Bhatt, S., & Sharma, S. (2026). Comparative Evaluation of Retention of Different Luting Cements for Im plant-Supported Crowns: An In Vitro Study. Academia Journal of Medicine, 9(1), 26-29. https://doi.org/10.48165/ajm.2026.9.01.7
Vancouver
I MS, Erraguntala H, Chaudhary V, Sojitra M, Bhatt S, Sharma S. Comparative Evaluation of Retention of Different Luting Cements for Im plant-Supported Crowns: An In Vitro Study. Academia Journal of Medicine. 2026;9(1):26-29. doi:10.48165/ajm.2026.9.01.7
BibTeX
@article{I2026,
author = {I, Mohammed Subhan and Erraguntala, Harshitha and Chaudhary, Vivek and Sojitra, Margi and Bhatt, Sumit and Sharma, Suchita},
title = {Comparative Evaluation of Retention of Different Luting Cements for Im plant-Supported Crowns: An In Vitro Study},
journal = {Academia Journal of Medicine},
year = {2026},
volume = {9},
number = {1},
pages = {26--29},
doi = {10.48165/ajm.2026.9.01.7}
}
EUVIMED