EUVIMEDEUVIMED entdecken
Crossref

Time savings when using IC-ECG navigation to confirm the PICC tip location compare to chest X-ray

Iveta Constantine, Magda Michaliková, Andrea Polanská, Zuzana Figurová, Adéla Kondé

Florence · 2025

DOI: 10.48095/ccflo2025152 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Florence, 2025. Verfasst von Iveta Constantine und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Peripherally inserted central catheters (PICCs) with the use of intracavitary electrocardiogram (IC-ECG) method are gaining more and more attention. The aim of this study was to support and add more evidence about feasibility, accuracy and safety of IC-ECG tip location comparing to a chest X-ray in order to eliminate unnecessary radiation and additional patient’s investigation. This study was performed by nurses led PICC team and it is the first nursing study in Czech Republic on this topic.

Methods

A single center, prospective, non-randomized clinical study. Data were collected over 3 years at University Hospital Ostrava, Czech Republic, from June 2020 to January 2023. The primary outcome was measurement of time elapsed between IC-ECG and chest X-ray confirmation, secondary outcome measured success rate using IC-ECG and confirming the tip of the catheter in cavo-atrial junction (CAJ).

Results

Data of 453 consecutive patients who underwent PICC insertion were analysed. The primary outcome showed the minimum time elapsed between IC-ECG and chest X-ray confirmation by physician was 1 min and the maximum time was 400 min, with the median waiting time of 80 min. Secondary outcome showed ­IC-ECG success rate in 84.8% (N = 384) of the sample.

Conclusion

IC-ECG confirmation method can be used by nursing teams safely and effectivelly without a risk for complications. It proved to be reliable method of confirming the tip of the catheter and allowing the use of PICC immediately post insertion without a delay in patient’s treatment.

Zitieren

APA

Constantine, I., Michaliková, M., Polanská, A., Figurová, Z., & Kondé, A. (2025). Time savings when using IC-ECG navigation to confirm the PICC tip location compare to chest X-ray. Florence. https://doi.org/10.48095/ccflo2025152

Vancouver

Constantine I, Michaliková M, Polanská A, Figurová Z, Kondé A. Time savings when using IC-ECG navigation to confirm the PICC tip location compare to chest X-ray. Florence. 2025. doi:10.48095/ccflo2025152

BibTeX
@article{Constantine2025,
  author = {Constantine, Iveta and Michaliková, Magda and Polanská, Andrea and Figurová, Zuzana and Kondé, Adéla},
  title = {Time savings when using IC-ECG navigation to confirm the PICC tip location compare to chest X-ray},
  journal = {Florence},
  year = {2025},
  doi = {10.48095/ccflo2025152}
}
Kostenlos starten →