Experimental Investigation of Composite Circular Encased GFRP I-Section Concrete Columns under Different Load Conditions
Engineering, Technology & Applied Science Research · 09.10.2024 · 14 (5) · 17286-17293
DOI: 10.48084/etasr.8521 ↗Kurz gefasst
Fachartikel in der Zeitschrift Engineering, Technology & Applied Science Research, online erschienen am 09.10.2024. Verfasst von Hiba Shihab Ahmed und 2 weiteren Autor:innen. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Pultruded materials made of Fiber-Reinforced Polymer (FRP) come in a broad range of shapes, such as bars, I-sections, C-sections, etc. FRP materials are starting to compete with steel as structural materials owing to their great resistance, low self-weight, and cheap maintenance costs, especially in corrosive conditions. This study aims to evaluate the effectiveness of a novel concrete Composite Column (CC) using Encased I-Section (EIS) as a reinforcement in contrast to traditional steel bars by using Glass Fiber-Reinforced Polymer (GFRP) as I-section (CC-EIS) to evaluate the effectiveness of the hybrid columns which have been built by combining GFRP profiles with concrete columns. To achieve the aims of this study, nine circular columns with a diameter of 150 mm and a height of 1000 mm were cast with compression strength equal to 42.4 MPa at the test day. The research involved three different types of reinforcement: Hybrid circular columns with GFRP I-section and 1% reinforcement ratio of steel bars, Hybrid circular columns with steel I-section and 1% reinforcement ratio of steel bars (the cross-section area of the I-section was the same for GFRP and for steel), and a reference column without an I-section. This study investigates the ultimate capacity, axial and lateral deformation, and failure mode of the circular columns under different loading conditions: concentric, eccentric (with eccentricities of 25 mm), and flexural loading. The results showed that the ultimate capacity of the composite columns using either encased steel I-section or GFRP I-section was higher than the traditional columns under all loading conditions. The concentric tested specimens, with steel I-section and with GFRP I-section, exceeded the ultimate strength of the reference specimen by 8.9% and 2.9%, respectively. Specimens with steel I-section and GFRP I-section achieved 11.9% and 9.7% higher ultimate strength than the reference specimens under a compression load of 25 mm eccentricity. Specimens with steel I-section and the specimens with GFRP I-section achieved ultimate strengths of 114.3% and 36.6% under flexural loading testing.
Zitieren
APA
Ahmed, H. S., Allawi, A., & Hindi, R. (2024). Experimental Investigation of Composite Circular Encased GFRP I-Section Concrete Columns under Different Load Conditions. Engineering, Technology & Applied Science Research, 14(5), 17286-17293. https://doi.org/10.48084/etasr.8521
Vancouver
Ahmed HS, Allawi A, Hindi R. Experimental Investigation of Composite Circular Encased GFRP I-Section Concrete Columns under Different Load Conditions. Engineering, Technology & Applied Science Research. 2024;14(5):17286-17293. doi:10.48084/etasr.8521
BibTeX
@article{Ahmed2024,
author = {Ahmed, Hiba Shihab and Allawi, Abbas and Hindi, Riyadh},
title = {Experimental Investigation of Composite Circular Encased GFRP I-Section Concrete Columns under Different Load Conditions},
journal = {Engineering, Technology & Applied Science Research},
year = {2024},
volume = {14},
number = {5},
pages = {17286--17293},
doi = {10.48084/etasr.8521}
}