EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimizing Tidal Sluice Gate Operations through Real-Time Salinity and Water Level Monitoring: A Case Study in Nghia Hung District, Ninh Binh-Vietnam

Bach Phuong Ho Thi, Chinh Do Van, Duc Nguyen Viet

Engineering, Technology & Applied Science Research · 11.08.2026 · 16 (4) · 38535-38542

DOI: 10.48084/etasr.19452 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Engineering, Technology & Applied Science Research, online erschienen am 11.08.2026. Verfasst von Bach Phuong Ho Thi und 2 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasing salinity intrusion in coastal estuaries poses a significant threat to agricultural productivity, demanding precise and timely sluice gate operations to reduce or eliminate the salinity effect. This study designed and deployed an integrated automated monitoring system for salinity and water level at the Binh Hai and Ba Cua sluices in Nghia Hung District, Ninh Binh, Vietnam, to replace inefficient manual monitoring methods. The system utilized Electrochemical (EC) sensors and hydrostatic pressure probes connected to a PAS-OA920 datalogger, transmitting data via a Global System for Mobile communications (GSM) cloud-based platform. During a one-month field trial (12 September-11 October 2023), the system experienced intermittent interruptions caused by power supply and communication instability under harsh estuarine conditions, which resulted in only seven days of complete manual and automated measurements being suitable for sensor evaluation. The water level sensor demonstrated excellent agreement with manual measurements (r = 0.98-0.99; MAE = 0.005-0.008 m), confirming its suitability for operational monitoring. In contrast, the salinity sensor showed limited agreement with manual titration measurements (MAE = 0.057-0.136‰), while the correlation coefficient was not informative (r = 0). Therefore, the results support the use of the water level sensor as a replacement for the manual monitoring procedure. However, the comparatively high MAE and zero correlation coefficient obtained for the salinity sensor do not support its complete replacement of laboratory-based titration; instead, with further performance improvements, it could be considered a supplementary monitoring tool. Despite these limitations, the near-continuous measurements enabled operators to identify freshwater intake windows more effectively, supporting water management for more than 8,833 ha of agricultural land. Nevertheless, these findings are based on only seven days of complete measurements, highlighting the need for further improvements in sensor performance, particularly for salinity monitoring, as well as enhanced connectivity and long-term reliability under harsh estuarine conditions.

Zitieren

APA

Thi, B. P. H., Van, C. D., & Viet, D. N. (2026). Optimizing Tidal Sluice Gate Operations through Real-Time Salinity and Water Level Monitoring: A Case Study in Nghia Hung District, Ninh Binh-Vietnam. Engineering, Technology & Applied Science Research, 16(4), 38535-38542. https://doi.org/10.48084/etasr.19452

Vancouver

Thi BPH, Van CD, Viet DN. Optimizing Tidal Sluice Gate Operations through Real-Time Salinity and Water Level Monitoring: A Case Study in Nghia Hung District, Ninh Binh-Vietnam. Engineering, Technology & Applied Science Research. 2026;16(4):38535-38542. doi:10.48084/etasr.19452

BibTeX
@article{Thi2026,
  author = {Thi, Bach Phuong Ho and Van, Chinh Do and Viet, Duc Nguyen},
  title = {Optimizing Tidal Sluice Gate Operations through Real-Time Salinity and Water Level Monitoring: A Case Study in Nghia Hung District, Ninh Binh-Vietnam},
  journal = {Engineering, Technology & Applied Science Research},
  year = {2026},
  volume = {16},
  number = {4},
  pages = {38535--38542},
  doi = {10.48084/etasr.19452}
}
Kostenlos starten →