Development and Preliminary Validation of a 69% Domestic Content (TKDN) Continuous Emission Monitoring System for Industrial Flue Gas Monitoring

Fajar, Winarni Monoarfa, Ahmad Zubair Sultan, M. Shidiq Yunus, Ardi Nugroho, Eymal Bahsar Demmalino

Engineering, Technology & Applied Science Research · 06.06.2026 · 16 (3) · 37119-37124

DOI: 10.48084/etasr.18689 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Engineering, Technology & Applied Science Research, online erschienen am 06.06.2026. Verfasst von Fajar und 5 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous Emission Monitoring Systems (CEMSs) are important for regulatory compliance and real-time emission monitoring in coal-fired power plants. However, many developing countries still depend on imported systems, which can limit domestic technological development and increase operational costs. This study presents the development and preliminary validation of a CEMS with 69% domestic content (Tingkat Komponen Dalam Negeri-TKDN). The system integrates locally manufactured mechanical components, data acquisition modules, and control systems with standardized gas analyzers for monitoring industrial flue gas emissions. Experimental validation was conducted using certified reference gases under controlled calibration conditions to evaluate measurement accuracy, repeatability, and operational performance. The system successfully measured the concentrations of CO₂, SO₂, CO, and O₂. A NOₓ monitoring channel using an electrochemical NO₂ sensor module was also integrated into the system design; however, quantitative validation of NOₓ measurements could not be completed due to sensor stability limitations during calibration testing. The results showed good agreement with reference instruments. Measurement errors were below 3% for SO₂, CO₂, and O₂, whereas CO measurements showed higher deviation during preliminary calibration. All evaluated gases demonstrated low variability during repeated measurements, indicating good repeatability and stable short-term system performance. Overall, the developed CEMS demonstrates promising potential for industrial emission monitoring and supports the development of domestic environmental monitoring technologies in developing countries.

Zitieren

APA

Fajar, Monoarfa, W., Sultan, A. Z., Yunus, M. S., Nugroho, A., & Demmalino, E. B. (2026). Development and Preliminary Validation of a 69% Domestic Content (TKDN) Continuous Emission Monitoring System for Industrial Flue Gas Monitoring. Engineering, Technology & Applied Science Research, 16(3), 37119-37124. https://doi.org/10.48084/etasr.18689

Vancouver

Fajar, Monoarfa W, Sultan AZ, Yunus MS, Nugroho A, Demmalino EB. Development and Preliminary Validation of a 69% Domestic Content (TKDN) Continuous Emission Monitoring System for Industrial Flue Gas Monitoring. Engineering, Technology & Applied Science Research. 2026;16(3):37119-37124. doi:10.48084/etasr.18689

BibTeX
@article{Fajar2026,
  author = {Fajar and Monoarfa, Winarni and Sultan, Ahmad Zubair and Yunus, M. Shidiq and Nugroho, Ardi and Demmalino, Eymal Bahsar},
  title = {Development and Preliminary Validation of a 69% Domestic Content (TKDN) Continuous Emission Monitoring System for Industrial Flue Gas Monitoring},
  journal = {Engineering, Technology & Applied Science Research},
  year = {2026},
  volume = {16},
  number = {3},
  pages = {37119--37124},
  doi = {10.48084/etasr.18689}
}
Kostenlos starten →