Performance and Economic Analysis of Power Factor Correction Strategies in UTeM Institutional Buildings Using Real Load Data and MATLAB Simulink
Engineering, Technology & Applied Science Research · 11.08.2026 · 16 (4) · 37839-37852
DOI: 10.48084/etasr.17491 ↗Kurz gefasst
Fachartikel in der Zeitschrift Engineering, Technology & Applied Science Research, online erschienen am 11.08.2026. Verfasst von Elia Erwani Hassan und 4 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The research paper introduces a quantitative comparison of two reactive power compensation methods of improving the power factor (PF) performance in institutional buildings: automated capacitor banks and synchronous condensers at Universiti Teknikal Malaysia Melaka (UTeM). Three academic buildings, namely the Faculty of Electrical Technology and Engineering (FTKE), the Faculty of Electronic and Computer Technology and Engineering (FTKEK), and the Faculty of Information and Communication Technology (FTMK), were measured with a three-phase power quality analyzer that met the IEC 61000-4-30 Class A standards at 400 V with a frequency of 50 Hz. The measurement results of active power, reactive power, and PF profiles were set into a MATLAB/Simulink simulation model to assess reactive power compensation under realistic operating conditions. The power factor improvement indicator (ΔPF) was used to measure technical performance with the help of the reactive power sizing sensitivity analysis. The regulated requirement of a PF correction target of 0.85 was applied to prevent the penalties on utility surcharges according to Tenaga Nasional Berhad (TNB) regulations. The results of the simulations suggest that both compensation methods are effective in enhancing the PF compared to the utility benchmark, with the system with a low baseline PF having a greater correction sensitivity. Automated capacitor banks offered a cost-efficient response to steady-state compensation, whereas synchronous condensers offered better dynamic reactive response power support and better voltage stability under varying load conditions. The results indicate that effective Power Factor Correction (PFC) strategies can significantly reduce reactive current flow, minimize distribution losses, and improve the utilization of real power, thereby providing a technically and economically viable approach for sustainable energy management in institutional electrical distribution networks.
Zitieren
APA
Hassan, E. E., Zaidi, N. A. F. M., Saharuddin, N. Z. B., Yasin, Z. M., & Bahaman, N. (2026). Performance and Economic Analysis of Power Factor Correction Strategies in UTeM Institutional Buildings Using Real Load Data and MATLAB Simulink. Engineering, Technology & Applied Science Research, 16(4), 37839-37852. https://doi.org/10.48084/etasr.17491
Vancouver
Hassan EE, Zaidi NAFM, Saharuddin NZB, Yasin ZM, Bahaman N. Performance and Economic Analysis of Power Factor Correction Strategies in UTeM Institutional Buildings Using Real Load Data and MATLAB Simulink. Engineering, Technology & Applied Science Research. 2026;16(4):37839-37852. doi:10.48084/etasr.17491
BibTeX
@article{Hassan2026,
author = {Hassan, Elia Erwani and Zaidi, Nurul Aimy Farzana Muhamad and Saharuddin, Nur Zawani Binti and Yasin, Zuhaila Mat and Bahaman, Nazrulazhar},
title = {Performance and Economic Analysis of Power Factor Correction Strategies in UTeM Institutional Buildings Using Real Load Data and MATLAB Simulink},
journal = {Engineering, Technology & Applied Science Research},
year = {2026},
volume = {16},
number = {4},
pages = {37839--37852},
doi = {10.48084/etasr.17491}
}
EUVIMED