Analysis of the Influence of Spacer Number on Hot-Spot Temperature Distribution in Distribution Transformers
Chinese Smart Grid Research · 28.03.2026 · 3 (1) · 1-9
DOI: 10.48014/csgr.20251225002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Chinese Smart Grid Research, online erschienen am 28.03.2026. Verfasst von Peike WEN und 4 weiteren Autor:innen.
Abstract (Originalsprache)
This paper investigates the influence of the number of oil-duct spacers on the temperature distribution of an oil-immersed distribution transformer based on a multi-physics field coupling method. Taking a 100 kVA oil-immersed distribution transformer as the research object, a comparative analysis is conducted on the magnetic flux density, loss density, temperature field, as well as winding displacement and stress distribution under three-phase short-circuit conditions for varying numbers of spacers. This allows for a quantitative evaluation of the impact of spacer number on the transformer’s temperature rise characteristics and winding short-circuit withstand capability. The results indicate that increasing the number of spacers enhances oil-duct flow resistance and weakens natural oil circulation, leading to elevated top-oil and hotspot temperatures. Conversely, an insufficient number of spacers results in excessive winding displacement and stress concentration under short-circuit conditions. By comprehensively considering thermal and mechanical performance, a reasonable range for the number of spacers in this type of distribution transformer is determined to be 16-22. Within this range, an effective balance can be achieved between acceptable temperature rise levels and winding stability under short-circuit scenarios.
Zitieren
APA
WEN, P., JIA, Y., WANG, L., JIANG, K., & GONG, S. (2026). Analysis of the Influence of Spacer Number on Hot-Spot Temperature Distribution in Distribution Transformers. Chinese Smart Grid Research, 3(1), 1-9. https://doi.org/10.48014/csgr.20251225002
Vancouver
WEN P, JIA Y, WANG L, JIANG K, GONG S. Analysis of the Influence of Spacer Number on Hot-Spot Temperature Distribution in Distribution Transformers. Chinese Smart Grid Research. 2026;3(1):1-9. doi:10.48014/csgr.20251225002
BibTeX
@article{WEN2026,
author = {WEN, Peike and JIA, Yanlei and WANG, Longfei and JIANG, Kaij and GONG, Sunjing},
title = {Analysis of the Influence of Spacer Number on Hot-Spot Temperature Distribution in Distribution Transformers},
journal = {Chinese Smart Grid Research},
year = {2026},
volume = {3},
number = {1},
pages = {1--9},
doi = {10.48014/csgr.20251225002}
}
EUVIMED