The Recent Advancements to Measure the Blood Pressure Using Photoplethysmography, Electrocardiogram, and Microchannel
Smart Wearable Technology · 02.09.2025 · 2 · A1
DOI: 10.47852/bonviewswt52026420 ↗Kurz gefasst
Fachartikel in der Zeitschrift Smart Wearable Technology, online erschienen am 02.09.2025. Verfasst von Hajar Danesh und 3 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Uncontrolled blood pressure poses significant health risks, making accurate measurement essential in healthcare. Conventional blood pressure measurement methods, typically using inflatable cuffs, can cause patient discomfort, tissue damage, and are unsuitable for long-term monitoring. Consequently, researchers are exploring noninvasive, cuffless methods that provide continuous and accurate blood pressure assessment. This article presents a comprehensive review of sensors and estimation models used in cuffless blood pressure monitors, with a focus on enhancing accuracy and minimizing calibration requirements. A literature search was conducted using Google Scholar and reputable journals, including IEEE, Frontiers, and MDPI, resulting in the selection of 35 relevant studies. The review examines innovative techniques based on electrical, mechanical, and optical sensors. Particular attention is given to photoplethysmography (PPG), electrocardiography (ECG), and bioimpedance (Bio-Z), which, when combined with advanced signal analysis and deep learning models, show promising results. PPG enables blood volume measurement at accessible sites like the fingertip or wrist, leveraging parameters such as pulse transit time. ECG, which directly reflects heart activity, is also widely used for blood pressure estimation. Recent advancements in machine learning have improved accuracy, with models such as HGCTNet (a hybrid CNN-Transformer architecture) achieving an error margin of 0.9 ± 6.5 mmHg for diastolic and 0.7 ± 8.3 mmHg for systolic blood pressures. Despite the potential, challenges remain, including the need for continuous calibration of PPG-based systems. Ongoing research aims to address these limitations by improving signal quality and developing robust algorithms. The demonstrated accuracy and reduced calibration requirements suggest that cuffless blood pressure monitoring technologies may soon become viable for widespread clinical and home use. Received: 10 June 2025 | Revised: 28 July 2025 | Accepted: 12 August 2025 Conflicts of Interest The authors declare that they have no conflicts of interest to this work. Data Availability Statement Data sharing is not applicable to this article as no new data were created or analyzed in this study. Author Contribution Statement Hajar Danesh: Conceptualization, Writing - review & editing. Hamidreza Shirzadfar: Conceptualization, Writing - review & editing. Mahla Manian: Investigation, Writing - original draft. Melika Pazhom: Investigation, Writing - original draft.
Zitieren
APA
Danesh, H., Shirzadfar, H., Manian, M., & Pazhom, M. (2025). The Recent Advancements to Measure the Blood Pressure Using Photoplethysmography, Electrocardiogram, and Microchannel. Smart Wearable Technology, 2, A1. https://doi.org/10.47852/bonviewswt52026420
Vancouver
Danesh H, Shirzadfar H, Manian M, Pazhom M. The Recent Advancements to Measure the Blood Pressure Using Photoplethysmography, Electrocardiogram, and Microchannel. Smart Wearable Technology. 2025;2:A1. doi:10.47852/bonviewswt52026420
BibTeX
@article{Danesh2025,
author = {Danesh, Hajar and Shirzadfar, Hamidreza and Manian, Mahla and Pazhom, Melika},
title = {The Recent Advancements to Measure the Blood Pressure Using Photoplethysmography, Electrocardiogram, and Microchannel},
journal = {Smart Wearable Technology},
year = {2025},
volume = {2},
pages = {A1},
doi = {10.47852/bonviewswt52026420}
}