EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Multilayer Shields' Buildup Factor for Gamma Ray Exposure

Mustafa Hashim, Abdul Rahman Muhammad, Kareem Mohammad

Mustansiriyah Journal of Pure and Applied Sciences · 30.06.2026 · 4 (2) · 149-155

DOI: 10.47831/mjpas.v4i2.333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mustansiriyah Journal of Pure and Applied Sciences, online erschienen am 30.06.2026. Verfasst von Mustafa Hashim und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Iron discs were coated on both sides with distinct layers of W, Bi, and Pb powders. Three multilayer samples (coated Fe plates with W), (coated Fe plates with Bi), and (coated Fe plates with Pb) were produced by stacking ten powder-coated Fe discs on top of one another and sealing them with epoxy. The average particle sizes for W, Bi, and Pb were found to be 35, 40, and 30 nm, respectively, based on the images obtained using the scanning electron microscopy (SEM) test. Using a gamma spectrometry system with a NaI (Tl) detector, the transmission factor (T %), radiation protection efficiency (RPE), and built-up factor (B) have been calculated for four distinct gamma energies. For every sample, T% increased as energy increased, and the powder utilized will determine how comparable the data are. The RPE% was 20% for lead-coated iron samples at 1332 MeV, the highest of all the samples. At lower energies, the RPE% for most samples was greater than 70%, and as energy increased, it steadily declined. According to the results, the gamma-ray buildup factor and gamma energy have an inverse relationship.

Zitieren

APA

Hashim, M., Muhammad, A. R., & Mohammad, K. (2026). Multilayer Shields' Buildup Factor for Gamma Ray Exposure. Mustansiriyah Journal of Pure and Applied Sciences, 4(2), 149-155. https://doi.org/10.47831/mjpas.v4i2.333

Vancouver

Hashim M, Muhammad AR, Mohammad K. Multilayer Shields' Buildup Factor for Gamma Ray Exposure. Mustansiriyah Journal of Pure and Applied Sciences. 2026;4(2):149-155. doi:10.47831/mjpas.v4i2.333

BibTeX
@article{Hashim2026,
  author = {Hashim, Mustafa and Muhammad, Abdul Rahman and Mohammad, Kareem},
  title = {Multilayer Shields' Buildup Factor for Gamma Ray Exposure},
  journal = {Mustansiriyah Journal of Pure and Applied Sciences},
  year = {2026},
  volume = {4},
  number = {2},
  pages = {149--155},
  doi = {10.47831/mjpas.v4i2.333}
}
Kostenlos starten →