EUVIMEDEUVIMED entdecken
Crossref

Performance evaluation of an improved international electro-technical commission based thermal modeling of power transformers under factory testing conditions

Vinit Mehta, Jayashri Vajpai

Journal of Thermal Engineering · 29.07.2026

DOI: 10.47481/jten.0078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Thermal Engineering, online erschienen am 29.07.2026. Verfasst von Vinit Mehta und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Power transformers play a vital role in power systems, from the generation of electrical energy through transmission and distribution to end consumers. They are often loaded near rated-load conditions during operation. This leads to increased losses and a rise in temperature in the power transformers. The thermal performance of power transformers is a critical factor influencing operational reliability and insulation life, yet standard International Electro technical Commission-based models often assume a constant ambient temperature, limiting their predictive accuracy under real operating conditions. The objective of this research is to develop an improved International Electro technical Commission- based thermal model that incorporates time-varying ambient temperature effects during transformer-type testing. The research method includes exponential equations that are validated against stepped-load data from a 5 MVA transformer, where the ambient temperature ranged between 27°C and 32°C during the experimentation. A comparative analysis showed that the improved model reduced the mean absolute error for oil temperature rise from 3.15% to 2.04%, and for winding temperature rise from 2.30% to 1.88%. Similarly, root-mean-square error and mean percentage error decreased by 30–40%, indicating a consistent improvement in predictive accuracy across metrics. These findings indicate that incorporating ambient temperature variability enables the model to more accurately reproduce both steady-state conditions and transient heating and cooling behavior, thereby aligning more closely with physical expectations. Inference from the results suggests that the improved model offers a scientifically rigorous yet computationally efficient alternative to more complex data-driven approaches. The novelty of this work lies in bridging the gap between oversimplified, constant-ambient International Electro technical Commission-based thermal models and computationally intensive methods, thereby providing a standards-consistent framework with enhanced realism. The outcomes have direct implications for transformer manufacturers, enabling more reliable type testing; for utilities, enabling improved insulation life assessment and overload management; and for standards developers, recommending integration of dynamic ambient effects into standard guidelines.

Zitieren

APA

Mehta, V., & Vajpai, J. (2026). Performance evaluation of an improved international electro-technical commission based thermal modeling of power transformers under factory testing conditions. Journal of Thermal Engineering. https://doi.org/10.47481/jten.0078

Vancouver

Mehta V, Vajpai J. Performance evaluation of an improved international electro-technical commission based thermal modeling of power transformers under factory testing conditions. Journal of Thermal Engineering. 2026. doi:10.47481/jten.0078

BibTeX
@article{Mehta2026,
  author = {Mehta, Vinit and Vajpai, Jayashri},
  title = {Performance evaluation of an improved international electro-technical commission based thermal modeling of power transformers under factory testing conditions},
  journal = {Journal of Thermal Engineering},
  year = {2026},
  doi = {10.47481/jten.0078}
}
Kostenlos starten →