EUVIMEDEUVIMED entdecken
Crossref

Energy and exergy analyses of a lab-scale open-cycle steam power plant at different boiler pressures

Abdul Samad Saleem, Luqman Ali Khan, Hasnain Ali Shah, Malik Sarmad Zahid

Journal of Thermal Engineering · 23.06.2026

DOI: 10.47481/jten.0037 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Thermal Engineering, online erschienen am 23.06.2026. Verfasst von Abdul Samad Saleem und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In contrast to conventional steam power plants, which employ high-pressure closed cycles, this study presents energy and exergy analyses of a non-conventional lab-scale steam power plant across different boiler pressures, with an emphasis on the effect of cycle openness. Energy loss from the condenser, turbine work, and thermal efficiency of the cycle have been investigated at different boiler pressures, using energy analysis. Exergy analysis is performed at varying boiler pressures to examine the exergy destruction in the boiler and the condenser, and to evaluate the cycle’s exergetic efficiency. Experimental results show that minimizing exergy loss in one component of the cycle by varying the boiler pressure may increase it in another component; therefore, an optimal boiler pressure was investigated. As boiler pressure increases, turbine work and efficiencies initially increase because of higher exergy input but subsequently decrease as exergy destruction rises. The optimum boiler pressure is around 2.6 bar, as it minimizes exergy destruction in the cycle and energy loss in the condenser. Because the exergy input is less than the corresponding heat input, the energy efficiency (5-6.5 %) is found to be lower than the exergetic efficiency (15-21 %). In contrast to previous literature on conventional closed-cycle power plants, the current study finds condenser exergy destruction (542-564 kJ/kg) higher than that of the boiler (20-98 kJ/kg); this is due to the lack of condensate recirculation and consequent exergy loss at the condenser’s open end.

Zitieren

APA

Saleem, A. S., Khan, L. A., Shah, H. A., & Zahid, M. S. (2026). Energy and exergy analyses of a lab-scale open-cycle steam power plant at different boiler pressures. Journal of Thermal Engineering. https://doi.org/10.47481/jten.0037

Vancouver

Saleem AS, Khan LA, Shah HA, Zahid MS. Energy and exergy analyses of a lab-scale open-cycle steam power plant at different boiler pressures. Journal of Thermal Engineering. 2026. doi:10.47481/jten.0037

BibTeX
@article{Saleem2026,
  author = {Saleem, Abdul Samad and Khan, Luqman Ali and Shah, Hasnain Ali and Zahid, Malik Sarmad},
  title = {Energy and exergy analyses of a lab-scale open-cycle steam power plant at different boiler pressures},
  journal = {Journal of Thermal Engineering},
  year = {2026},
  doi = {10.47481/jten.0037}
}
Kostenlos starten →