Analytical parametric study of an evacuated tube solar air heater with perforated twisted tape for industrial heating applications
Isı Bilimi ve Tekniği Dergisi · 30.10.2026 · 46 (2) · 229-241
DOI: 10.47480/isibted.1892581 ↗Kurz gefasst
Fachartikel in der Zeitschrift Isı Bilimi ve Tekniği Dergisi, online erschienen am 30.10.2026. Verfasst von Karthi K und 3 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben.
Abstract (Originalsprache)
A major challenge in creating a vacuum solar tube air collector for industrial use is selecting the optimal thermal networks to reach the desired temperature for a specific flow rate. To develop a thermal network model using empirical correlations for industrial process heat applications, a theoretical analysis is performed to evaluate design features like the diameter and length of the evacuated tubes, as well as the quantity of tubes in a module, all of which impact thermal performance. The results of the design parametric study indicate that a collector system is best characterized by 20 evacuated tubes, each with an absorber and transparent diameters of 47 mm & 58 mm length of 1800 mm, respectively. Additionally, as the number of collectors in a series network increase, there is a notable reduction in the temperature rise for each collection. Based on the thermal network composed of two modules operating at 300 kg/h can provide optimum performance. The results indicate that the proposed evacuated tube solar system is capable of efficiently supplying hot air at temperatures between 80 and 100 °C, making it suitable for a range of industrial process heating applications.
Zitieren
APA
K, K., Adaikalasamy, V., Selvaraj, V., & R, V. (2026). Analytical parametric study of an evacuated tube solar air heater with perforated twisted tape for industrial heating applications. Isı Bilimi ve Tekniği Dergisi, 46(2), 229-241. https://doi.org/10.47480/isibted.1892581
Vancouver
K K, Adaikalasamy V, Selvaraj V, R V. Analytical parametric study of an evacuated tube solar air heater with perforated twisted tape for industrial heating applications. Isı Bilimi ve Tekniği Dergisi. 2026;46(2):229-241. doi:10.47480/isibted.1892581
BibTeX
@article{K2026,
author = {K, Karthi and Adaikalasamy, Veerakumar and Selvaraj, Vijayan and R, Venkatramanan},
title = {Analytical parametric study of an evacuated tube solar air heater with perforated twisted tape for industrial heating applications},
journal = {Isı Bilimi ve Tekniği Dergisi},
year = {2026},
volume = {46},
number = {2},
pages = {229--241},
doi = {10.47480/isibted.1892581}
}
EUVIMED