Thermal–Hydraulic Performance of Shell-and-Tube Heat Exchangers with Disc-and-Ring Baffles and a Central Tube-Free Zone

Jinghao Yu, Huabin Wen

Isı Bilimi ve Tekniği Dergisi · 01.05.2026 · 46 (1) · 90-103

DOI: 10.47480/isibted.1767278 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Isı Bilimi ve Tekniği Dergisi, online erschienen am 01.05.2026. Verfasst von Jinghao Yu und 1 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a detailed numerical investigation of the heat transfer performance of a shell-and-tube heat exchanger featuring a distinctive tube bundle configuration. In this design, no heat exchange tubes are arranged within the circular region at the center of the support structure, resulting in a tube bundle layout with a central cavity. The analysis fo-cuses on the effect of different non-tube region sizes on overall heat transfer characteris-tics. The results show that self-heat exchange within the non-tube region significantly en-hances the uniformity of heat distribution between the shell side and tube side. Moreover, the uniformity improves with the increase in the non-tube region size, showing a positive correlation. Enlarging the non-tube region can effectively reduce energy consumption and improve operational efficiency and economic performance. However, this also results in a decrease in heat transfer intensity due to the reduction of the heat exchange surface area. When the size of the tube-free region increases from 140 mm to 440 mm, the heat transfer uniformity improves by 65.9%, whereas the shell-side heat transfer coefficient decreases by 22.1%. A comprehensive performance evaluation based on the TOPSIS deci-sion-making method indicates that a tube-free region size of 380 mm provides the optimal balance between heat transfer intensity and uniformity. Under this condition, the shell-side heat transfer coefficient reaches 6594 W/(m²·K), and the relative standard de-viation of the tube-side outlet temperature is 0.601, representing the best overall perfor-mance.

Zitieren

APA

Yu, J., & Wen, H. (2026). Thermal–Hydraulic Performance of Shell-and-Tube Heat Exchangers with Disc-and-Ring Baffles and a Central Tube-Free Zone. Isı Bilimi ve Tekniği Dergisi, 46(1), 90-103. https://doi.org/10.47480/isibted.1767278

Vancouver

Yu J, Wen H. Thermal–Hydraulic Performance of Shell-and-Tube Heat Exchangers with Disc-and-Ring Baffles and a Central Tube-Free Zone. Isı Bilimi ve Tekniği Dergisi. 2026;46(1):90-103. doi:10.47480/isibted.1767278

BibTeX
@article{Yu2026,
  author = {Yu, Jinghao and Wen, Huabin},
  title = {Thermal–Hydraulic Performance of Shell-and-Tube Heat Exchangers with Disc-and-Ring Baffles and a Central Tube-Free Zone},
  journal = {Isı Bilimi ve Tekniği Dergisi},
  year = {2026},
  volume = {46},
  number = {1},
  pages = {90--103},
  doi = {10.47480/isibted.1767278}
}
Kostenlos starten →