EUVIMEDEUVIMED entdecken
Crossref

DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION

Umut Barış YILMAZ, Oğuz TURGUT, Nuri YÜCEL, Muhammed İlter BERBEROĞLU

Isı Bilimi ve Tekniği Dergisi · 2022

DOI: 10.47480/isibted.1107486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Isı Bilimi ve Tekniği Dergisi, 2022. Verfasst von Umut Barış YILMAZ und 3 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

n-heptane pool fire was numerically and experimentally investigated in a 1:100 scaled metro station. Fire Dynamics Simulator (FDS v6.7.5) has been applied to investigate smoke and temperature distribution by implementing different design curves in the station. Experimental and numerical studies were performed for 10 ml n-heptane fuel under zero piston effect. To develop performance-based design and to obtain reliable fire simulation results for structures, reasonable input conditions are essential for numerical studies. The aim of the study is to select most suitable fire design curve and make the numerical study independent of the experimental results for small scale hydrocarbon pool fires. In this study, t2, tanh, Eurocode 1 (BS EN 1991-1-2), exponential, and quadratic fire curves were investigated and validated with experimental results. The numerical results obtained using FDS were validated with experimental data and good agreement was observed for all design fire curves except quadratic one. It was observed that the exponential design fire curve predicted more similarly to the experimental data over the fire duration including growth, fully developed and decay phases. Regardless of the experimental results, it was seen that the temperature distribution results obtained from the numerical study using exponential fire design curve and the radiation / turbulence parameters obtained from the literature were found to have an average of 5% difference with the experimental results. It was also seen that the t2 and tanh curves have acceptable differences of 6.92% and 9.02%, respectively, and the Eurocode HC is less suitable than the other curves with a difference of 12.17%. Therefore, it can be said that in small scale hydrocarbon pool fires, fire design can be done using exponential design curve.

Zitieren

APA

YILMAZ, U. B., TURGUT, O., YÜCEL, N., & BERBEROĞLU, M. İ. (2022). DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION. Isı Bilimi ve Tekniği Dergisi. https://doi.org/10.47480/isibted.1107486

Vancouver

YILMAZ UB, TURGUT O, YÜCEL N, BERBEROĞLU Mİ. DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION. Isı Bilimi ve Tekniği Dergisi. 2022. doi:10.47480/isibted.1107486

BibTeX
@article{YILMAZ2022,
  author = {YILMAZ, Umut Barış and TURGUT, Oğuz and YÜCEL, Nuri and BERBEROĞLU, Muhammed İlter},
  title = {DESIGN FIRE CURVE SELECTION OF SMALL SCALE POOL FIRES IN A SCALED METRO STATION},
  journal = {Isı Bilimi ve Tekniği Dergisi},
  year = {2022},
  doi = {10.47480/isibted.1107486}
}
Kostenlos starten →