Shape and size of foveal avascular zone in normal subjects using optical coherence tomography angiography (OCTA): A retrospective analysis

Adeel Chaudhry, Muhammad Moin, Tayyaba Gul Malik, Mehreen Akram, Abdullah Irfan, Ahsan Mehmood

Journal of the Pakistan Medical Association · 28.05.2026 · 76 (06) · 863-865

DOI: 10.47391/jpma.22735 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Pakistan Medical Association, online erschienen am 28.05.2026. Verfasst von Adeel Chaudhry und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Lahore General Hospital, Lahore, Pakistan. Hauptthemen laut MEDLINE: Fovea Centralis, Tomography, Optical Coherence, Retinal Vessels. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the shape and size of foveal avascular zone in terms of perimeter, circularity, roundness and axial ratio using optical coherence tomography angiography.

Method

The retrospective study was conducted at the Yaqeen Vison Clinic, Lahore, in August 2023, and comprised data from January 2020 to December 2022 of patients of either gender aged 17-84 years having best corrected visual acuity >6/6 and normal retina. Foveal avascular zone was measured using optical coherence tomography angiography. Perimeter, circularity, axial ratio and roundness were assessed. Only one eye of each subject was considered for analysis. Data was analysed using SPSS 25.

Results

Of the 208 patients, 108(52%) were females and 100(48%) were males. The overall mean age was 56.55±16.6 years. There were 106(51%) right eyes and 102(49%) left eyes. Mean values for perimeter, circularity, axial ratio and roundness were 2.18±0.3mm, 0.93±0.12, 1.18±0.23and 8.09±1.41, respectively. There was a significant association of foveal avascular zone perimeter with age (p=0.001). Circularity, axial ratio and roundness did not have significant variations with age (p>0.05).

Conclusion

Foveal avascular zone in Pakistani individuals was found to be larger, and there was more variation in foveal avascular zone size than shape, making shape a more reliable factor in retinal vascular diseases. Key Words: Fovea centralis, Retina, OCT, Fluorescein angiography.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fovea CentralisTomography, Optical CoherenceRetinal VesselsHumansMaleFemaleMiddle AgedRetrospective StudiesAdultAgedAged, 80 and overAdolescentYoung AdultFluorescein Angiography

Stichwörter der Autor:innen

Fovea centralis, Retina, OCT, Fluorescein angiography.

Autor:innen und Institutionen

  • Department of Ophthalmology, Lahore General Hospital, Lahore, Pakistan.

Zitieren

APA

Chaudhry, A., Moin, M., Malik, T. G., Akram, M., Irfan, A., & Mehmood, A. (2026). Shape and size of foveal avascular zone in normal subjects using optical coherence tomography angiography (OCTA): A retrospective analysis. Journal of the Pakistan Medical Association, 76(06), 863-865. https://doi.org/10.47391/jpma.22735

Vancouver

Chaudhry A, Moin M, Malik TG, Akram M, Irfan A, Mehmood A. Shape and size of foveal avascular zone in normal subjects using optical coherence tomography angiography (OCTA): A retrospective analysis. Journal of the Pakistan Medical Association. 2026;76(06):863-865. doi:10.47391/jpma.22735

BibTeX
@article{Chaudhry2026,
  author = {Chaudhry, Adeel and Moin, Muhammad and Malik, Tayyaba Gul and Akram, Mehreen and Irfan, Abdullah and Mehmood, Ahsan},
  title = {Shape and size of foveal avascular zone in normal subjects using optical coherence tomography angiography (OCTA): A retrospective analysis},
  journal = {Journal of the Pakistan Medical Association},
  year = {2026},
  volume = {76},
  number = {06},
  pages = {863--865},