EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Computed tomography liver volumetry in living donor liver transplantation: influence of the slice thickness on the volume calculation

Tooba Fatima, Muhammad Salman Rafique, Sana Kundi, Tahir Malik, Faryal Ijaz, Sahar Zulfiqar

Journal of the Pakistan Medical Association · 2025

DOI: 10.47391/jpma.11539 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Pakistan Medical Association, 2025. Verfasst von Tooba Fatima und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Pakistan Kidney and Liver Institute and Research Center, Lahore, Pakistan. Hauptthemen laut MEDLINE: Liver Transplantation, Living Donors, Liver, Multidetector Computed Tomography. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the effect of slice thickness on multidetector computed tomography-based preoperative liver volumetry, and to compare the time consumed during volumetry between thin and thick slices.

Method

The retrospective study was conducted at the Pakistan Kidney and Liver Institute and Research Centre, Lahore, Pakistan, and comprised data from September 2022 to January 2023 of patients who underwent donor hepatectomy. Liver volumetry was done on thick 5mm and thin 0.625mm slices, and the consumed time was calculated. The calculated volumes were then compared to the actual per-operative graft volume. Data was analysed using SPSS 20.

Results

Of the 30 donors, 20(66.7%) were males and 10(33.3%) were females. The overall mean age was 26 years (range: 19-44 years, SD=6.25). The mean estimated graft volume on thick slices was 668.57±169.83g compared to 693.70±174.78g on thin slices (p>0.05). The time taken to calculate estimated graft volume on thick slices was 7.29±0.97 minutes compared to 44.07±4.78 minutes on thin slices (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver TransplantationLiving DonorsLiverMultidetector Computed TomographyHumansFemaleMaleAdultRetrospective StudiesOrgan SizeHepatectomyYoung AdultPakistan

Stichwörter der Autor:innen

Multidetector computed tomography-based preoperative liver volumetry, Total liv…

Autor:innen und Institutionen

  • Department of Radiology, Pakistan Kidney and Liver Institute and Research Center, Lahore, Pakistan.

Zitieren

APA

Fatima, T., Rafique, M. S., Kundi, S., Malik, T., Ijaz, F., & Zulfiqar, S. (2025). Computed tomography liver volumetry in living donor liver transplantation: influence of the slice thickness on the volume calculation. Journal of the Pakistan Medical Association. https://doi.org/10.47391/jpma.11539

Vancouver

Fatima T, Rafique MS, Kundi S, Malik T, Ijaz F, Zulfiqar S. Computed tomography liver volumetry in living donor liver transplantation: influence of the slice thickness on the volume calculation. Journal of the Pakistan Medical Association. 2025. doi:10.47391/jpma.11539

BibTeX
@article{Fatima2025,
  author = {Fatima, Tooba and Rafique, Muhammad Salman and Kundi, Sana and Malik, Tahir and Ijaz, Faryal and Zulfiqar, Sahar},
  title = {Computed tomography liver volumetry in living donor liver transplantation: influence of the slice thickness on the volume calculation},
  journal = {Journal of the Pakistan Medical Association},
  year = {2025},
  doi = {10.47391/jpma.11539}
}
Kostenlos starten →