A comparison study of 589 and 650 nm on improving stored whole blood stability by irradiation with a low-power diode pumping solid-state laser
Journal of the Pakistan Medical Association · 2024
DOI: 10.47391/jpma-bagh-16-38 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of the Pakistan Medical Association, 2024. Verfasst von Safa Hassan Mohammed und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology, Mustansiriyah University, Baghdad, Iraq. Hauptthemen laut MEDLINE: Blood Preservation, Hemolysis, Erythrocytes, Lasers, Solid-State. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To assess the effects of diode-pumped solid-state laser irradiation with 589nm and 650nm wavelengthson the stability of stored red blood cells in vitro.
Method
This is an intervention study that was conducted from April to July 2021 at the Physiology and MedicalPhysics Laboratory, College of Medicine, Mustansiriyah University, Baghdad, Iraq, and comprised samples ofhealthy, adult human blood that were put in tubes with citrate-phosphate dextrose-adenine as an anticoagulant.The blood sample was divided into eight equal aliquots and stored for 21 days at 4ºC. The stability test was done ondays 0, 7, 14 and 21 of storage time for non-irradiated and radiated aliquots. For 15 minutes, the irradiated aliquotswere subjected to a diode-pumped solid-state laser with a wavelength of 589nm or a laser with a wavelength of650nm at frequencies of 30, 50 and 70 J/cm². Data was analysed using SPSS 24.
Results
Exposure of the whole blood to 589nm and a radiation dose of 70J/cm², 50J/cm² and 30J/cm² wasassociated with a significant reduction in the percentage of haemolysis that ranged 23-42% throughout the wholestorage time. Exposure of the whole blood to 650nm wavelength low-level laser therapy and a radiation dose of70J/cm², 50J/cm² and 30J/cm² was associated with much less reduction in the percentage of haemolysis that ranged5-9% throughout the whole storage time.
Conclusions
Both 589nm and to some extent 650nm low-level laser irradiation generally reduced haemolysis. Thewavelength of 589nm lasers had a more effective influence than the 650nm counterpart in improving the stored redblood cells.Key Words: Lasers, Solid-State, Hemolysis, Light Therapy, Erythrocytes, Anticoagulants, Radiation, Phosphates,Citrates, Glucose, Adenine
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physiology, Mustansiriyah University, Baghdad, Iraq.
Zitieren
APA
Mohammed, S. H., Al Musawi, M. S., & Al-Gailani, B. T. (2024). A comparison study of 589 and 650 nm on improving stored whole blood stability by irradiation with a low-power diode pumping solid-state laser. Journal of the Pakistan Medical Association. https://doi.org/10.47391/jpma-bagh-16-38
Vancouver
Mohammed SH, Al Musawi MS, Al-Gailani BT. A comparison study of 589 and 650 nm on improving stored whole blood stability by irradiation with a low-power diode pumping solid-state laser. Journal of the Pakistan Medical Association. 2024. doi:10.47391/jpma-bagh-16-38
BibTeX
@article{Mohammed2024,
author = {Mohammed, Safa Hassan and Al Musawi, Mustafa Salih and Al-Gailani, Bassam Talib},
title = {A comparison study of 589 and 650 nm on improving stored whole blood stability by irradiation with a low-power diode pumping solid-state laser},
journal = {Journal of the Pakistan Medical Association},
year = {2024},
doi = {10.47391/jpma-bagh-16-38}
}
EUVIMED