EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation

Nada Abdul Salam, Amal Yousif Al-Yasiri, Bassam Talib Al-Gailani

Journal of the Pakistan Medical Association · 2024

DOI: 10.47391/jpma-bagh-16-10 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Pakistan Medical Association, 2024. Verfasst von Nada Abdul Salam und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology, Mustansiriyah University, Baghdad, Iraq. Hauptthemen laut MEDLINE: Pulse Wave Analysis, Fingers, Brachial Artery, Plethysmography. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.

Method

The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.

Results

There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p0.05).

Conclusion

The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulse Wave AnalysisFingersBrachial ArteryPlethysmographyHumansMaleYoung AdultEndothelium, VascularVasodilationHyperemiaVascular StiffnessAdult

Stichwörter der Autor:innen

Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, P…

Autor:innen und Institutionen

  • Department of Physiology, Mustansiriyah University, Baghdad, Iraq.
  • Department of Basic Sciences, University of Baghdad.

Zitieren

APA

Salam, N. A., Al-Yasiri, A. Y., & Al-Gailani, B. T. (2024). Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation. Journal of the Pakistan Medical Association. https://doi.org/10.47391/jpma-bagh-16-10

Vancouver

Salam NA, Al-Yasiri AY, Al-Gailani BT. Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation. Journal of the Pakistan Medical Association. 2024. doi:10.47391/jpma-bagh-16-10

BibTeX
@article{Salam2024,
  author = {Salam, Nada Abdul and Al-Yasiri, Amal Yousif and Al-Gailani, Bassam Talib},
  title = {Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation},
  journal = {Journal of the Pakistan Medical Association},
  year = {2024},
  doi = {10.47391/jpma-bagh-16-10}
}
Kostenlos starten →