EUVIMEDEUVIMED entdecken
Systematische Übersicht

AI-Assisted Occlusal Design and Adjustment in Prosthodontics: A Systematic Review of Fit Accuracy, Occlusal Trueness and Workflow Efficiency

Salah A. Yousief, Nasser Hussein Shaheen, Dina Wafik Elkassas, Hala Aly Maher Ragab, Dalia A. Magdi

Journal of Pioneering Medical Sciences · 05.11.2026 · 15 (10) · 216-226

DOI: 10.47310/jpms2026151032 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Pioneering Medical Sciences, online erschienen am 05.11.2026. Verfasst von Salah A. Yousief und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Artificial Intelligence (AI) based tools are increasingly used in prosthodontic design and occlusal analysis. They now appear at several steps of the digital workflow: crown design, registration of the occlusal relationship and correction of virtual occlusal contacts. It is not clear whether these tools give restorations that fit and occlude as well as those made with conventional workflows. This systematic review summarises the evidence on AI-assisted occlusal design and adjustment, with technical accuracy as the primary outcome.

Methods

The review followed PRISMA 2020 and was not registered in advance. PubMed, Scopus and the Cochrane Library were searched for English-language articles published from 2015 to 2025. Eligible studies compared an AI-based tool for crown design, occlusal registration or occlusal contact correction with a conventional workflow. Two reviewers independently screened studies, extracted data and assessed risk of bias, using an adapted QUIN tool for laboratory studies and ROBINS-I for clinical studies. Results were synthesised narratively by intervention and outcome.

Results

The search identified 150 records and 12 studies met the inclusion criteria: two comparative clinical studies (17%), one laboratory study with three supplementary clinical cases (8%) and nine laboratory studies (75%). No randomised trial was found. No study reported follow-up beyond the scanning or seating visit and none reported validated patient-reported outcomes. In a paired clinical study of 62 patients, AI-designed crowns were equivalent to conventionally designed crowns for most marginal and internal gap measures, but the lingual marginal gap and the occlusal discrepancy were larger with AI design (149±66 Vs 105±63 μm; mean difference 43.9 μm, 90% CI 38.6 to 49.4, outside the ±15 μm equivalence margin). In laboratory studies that measured it, AI crown design shortened design time. AI-based occlusal registration was less accurate than the scanner’s own articulation in three of four studies of the same platform. AI-driven Occlusal Contact Adjustment (AI-OCA) improved the trueness of virtual occlusal records at some interarch distances and reduced it at others. Four studies came from one research group using one platform. Heterogeneity precluded meta-analysis.

Conclusion

The available studies measure technical accuracy at the time of fabrication. They say little about long-term clinical performance or patient benefit. AI-assisted crown design matched conventional design on most fit measures but produced larger occlusal discrepancies and results for AI-based registration and contact correction were mixed and depended on scanner and edentulous span. These findings are preliminary and should be treated as hypotheses. Well-designed clinical trials with standardized outcomes and long follow-up are needed before routine adoption.

Zitieren

APA

Yousief, S. A., Shaheen, N. H., Elkassas, D. W., Ragab, H. A. M., & Magdi, D. A. (2026). AI-Assisted Occlusal Design and Adjustment in Prosthodontics: A Systematic Review of Fit Accuracy, Occlusal Trueness and Workflow Efficiency. Journal of Pioneering Medical Sciences, 15(10), 216-226. https://doi.org/10.47310/jpms2026151032

Vancouver

Yousief SA, Shaheen NH, Elkassas DW, Ragab HAM, Magdi DA. AI-Assisted Occlusal Design and Adjustment in Prosthodontics: A Systematic Review of Fit Accuracy, Occlusal Trueness and Workflow Efficiency. Journal of Pioneering Medical Sciences. 2026;15(10):216-226. doi:10.47310/jpms2026151032

BibTeX
@article{Yousief2026,
  author = {Yousief, Salah A. and Shaheen, Nasser Hussein and Elkassas, Dina Wafik and Ragab, Hala Aly Maher and Magdi, Dalia A.},
  title = {AI-Assisted Occlusal Design and Adjustment in Prosthodontics: A Systematic Review of Fit Accuracy, Occlusal Trueness and Workflow Efficiency},
  journal = {Journal of Pioneering Medical Sciences},
  year = {2026},
  volume = {15},
  number = {10},
  pages = {216--226},
  doi = {10.47310/jpms2026151032}
}
Kostenlos starten →