EUVIMEDEUVIMED entdecken
Crossref

Comparative Assessment of Presumptive and Field-Based Soil Bearing Capacity in Cabanatuan City, Philippines

Franz Justine M. Valdez, Harold Glenn M. Licauan, Reynold Joshua DG. Santos, John Mark C. Mirano, Julie Jilianie C. Peña, Alfredo P. Gonzales jr., Rosel V. Babalcon

Engineering and Technology Journal · 26.05.2026 · 11 (05)

DOI: 10.47191/etj/v11i05.38 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Engineering and Technology Journal, online erschienen am 26.05.2026. Verfasst von Franz Justine M. Valdez und 6 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This research presents a geotechnical comparative screening between theoretical and empirical soil bearing capacities across 13 selected data nodes in Cabanatuan City. Utilizing the Philippine Geoportal database for initial soil classification, the study identified a subsurface dominated by Fine Sand and various Loams, reflecting the alluvial depositional history of the Pampanga River Basin. Theoretical baselines were established using IBC 2024 presumptive allowable bearing capacities, yielding a constrained range of 71.82 kPa to 95.76 kPa. Conversely, site-specific Standard Penetration Test (SPT) data from available DPWH borehole logs were analyzed. Using empirical correlations to derive allowable bearing capacities (qfield) from N-values, results revealed a highly heterogeneous subsurface ranging from 45 kPa to 225 kPa. While the IBC framework was conservative in 62% of locations, field-based values in 5 out of 13 sampled sites exhibited lower field-based values than the corresponding IBC presumptive values. This indicates potentially unconservative assumptions in specific zones if presumptive values are utilized without site-specific verification. The study concludes that international codes provide a necessary administrative baseline but cannot fully capture the observed 180 KPa variation among the investigated samples. Consequently, site-specific geotechnical investigations remain indispensable for ensuring structural integrity and design optimization in complex alluvial environments.

Zitieren

APA

Valdez, F. J. M., Licauan, H. G. M., Santos, R. J. D., Mirano, J. M. C., Peña, J. J. C., jr., A. P. G., & Babalcon, R. V. (2026). Comparative Assessment of Presumptive and Field-Based Soil Bearing Capacity in Cabanatuan City, Philippines. Engineering and Technology Journal, 11(05). https://doi.org/10.47191/etj/v11i05.38

Vancouver

Valdez FJM, Licauan HGM, Santos RJD, Mirano JMC, Peña JJC, jr. APG, et al. Comparative Assessment of Presumptive and Field-Based Soil Bearing Capacity in Cabanatuan City, Philippines. Engineering and Technology Journal. 2026;11(05). doi:10.47191/etj/v11i05.38

BibTeX
@article{Valdez2026,
  author = {Valdez, Franz Justine M. and Licauan, Harold Glenn M. and Santos, Reynold Joshua DG. and Mirano, John Mark C. and Peña, Julie Jilianie C. and jr., Alfredo P. Gonzales and Babalcon, Rosel V.},
  title = {Comparative Assessment of Presumptive and Field-Based Soil Bearing Capacity in Cabanatuan City, Philippines},
  journal = {Engineering and Technology Journal},
  year = {2026},
  volume = {11},
  number = {05},
  doi = {10.47191/etj/v11i05.38}
}
Kostenlos starten →