EUVIMEDEUVIMED entdecken
Crossref

Comparative evaluation of MinION and Nanoporus nanopore sequencers in identification of pathogen nucleic acids

D. A. Grigoryan, I. F. Stetsenko, B. S. Gukov, A. D. Matsvay, G. A. Shipulin

Extreme Medicine · 2025

DOI: 10.47183/mes.2024-242 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Extreme Medicine, 2025. Verfasst von D. A. Grigoryan und 4 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Nanopore sequencing technologies have become routine methods in science and medicine, being widely used in the study of pathogen diversity and distribution and playing a key role in field epidemiology.

Objective

Comparative evaluation of the functional capabilities of third-generation MinION and Nanoporus sequencers in the detection of pathogens in biological material, including comparison of the as-determined taxonomic composition with the results obtained using the second-generation MiSeq (Illumina) reference platform. Materials and methods. A total of 138 archival DNA samples with known taxonomic composition (14 families, 20 genus, and 43 species of viral and bacterial pathogens; altogether 169 pathogens) were analyzed. MinION and Nanoporus nanopore sequencers with original R9.4.1 and R10.4.1 flow cells (ONT), as well as the high-performance MiSeq (Illumina) platform were used for preliminary identification of the composition of samples containing different titers of pathogen nucleic acids belonging to various taxonomic groups. Comparative evaluation of the obtained data (number of sequences, average read quality scores (Qscore) for each nucleotide, GC-content of sequences, sequence length distribution, read duplication level) was performed using the MultiQC bioinformatics tool (version 1.20).

Results

The MinION and Nanoporus devices identified 98.8% and 97.6% of pathogens, respectively, including understudied or new viruses. The use of the latest-version flow cell on both devices significantly reduced the share of low-quality reads. The findings demonstrate a high degree of correlation between the results obtained by the second- and third-generation sequencers, which confirms the comparability and interchangeability of these technologies for the purposes of pathogen nucleic acid identification.

Conclusions

The study results demonstrate the potential of MinION and Nanoporus nanopore sequencers for epidemiologic surveillance. These devices are capable of identifying pathogens of different nature with high accuracy and, due to their compactness and portability, facilitating the diagnostics and monitoring of infectious diseases.

Zitieren

APA

Grigoryan, D. A., Stetsenko, I. F., Gukov, B. S., Matsvay, A. D., & Shipulin, G. A. (2025). Comparative evaluation of MinION and Nanoporus nanopore sequencers in identification of pathogen nucleic acids. Extreme Medicine. https://doi.org/10.47183/mes.2024-242

Vancouver

Grigoryan DA, Stetsenko IF, Gukov BS, Matsvay AD, Shipulin GA. Comparative evaluation of MinION and Nanoporus nanopore sequencers in identification of pathogen nucleic acids. Extreme Medicine. 2025. doi:10.47183/mes.2024-242

BibTeX
@article{Grigoryan2025,
  author = {Grigoryan, D. A. and Stetsenko, I. F. and Gukov, B. S. and Matsvay, A. D. and Shipulin, G. A.},
  title = {Comparative evaluation of MinION and Nanoporus nanopore sequencers in identification of pathogen nucleic acids},
  journal = {Extreme Medicine},
  year = {2025},
  doi = {10.47183/mes.2024-242}
}
Kostenlos starten →